Emerson MODBUS 485 Manuel D’Utilisation
![Emerson](https://files.manualsbrain.com/attachments/1ef3aaad462e024fde6cecf537a4c6c781334d44/common/fit/150/50/6dab323528eefa0342baa74a10c15551c3b956250cf9d62f2117dcdf42a7/brand_logo.jpeg)
Modbus 485 and Modbus IP Protocols - Thermal Management Products
9
Liebert
®
IntelliSlot
®
Modbus/BACnet IP
Electric Reheater Hours Exceeded 2
10085
—
1
Active on Alarm
1, 2, 3, 4, 5, 6
Electric Reheater Hours Exceeded 3
10086
—
1
Active on Alarm
1, 2, 3, 4, 5, 6
Hot Water / Hot Gas Valve Hours Exceeded
10087
—
1
Active on Alarm
1, 2, 3, 4, 5, 6
Humidifier Hours Exceeded
10088
—
1
Active on Alarm
1, 2, 3, 4, 5, 6
Dehumidifier Hours Exceeded
10089
—
1
Active on Alarm
1, 2, 3, 4, 5, 6
Unit Communication Lost
10091
—
1
Active on Alarm
1, 2, 3, 4, 5, 6
Master Unit Communication Lost
10092
—
1
Active on Alarm
1, 2, 3, 4, 5, 6
Unit Code Missing
10094
—
1
Active on Alarm
1, 2, 3, 4, 5, 6
Service Required
10098
—
1
Active on Alarm
1, 2, 3, 4, 5, 6
Humidifier Control Board Not Detected
10099
—
1
Active on Alarm
1, 2, 3, 4, 5, 6
Customer Input 1
10104
—
1
Active on Alarm
1, 2, 3, 4, 5, 6
Customer Input 2
10105
—
1
Active on Alarm
1, 2, 3, 4, 5, 6
Customer Input 3
10106
—
1
Active on Alarm
1, 2, 3, 4, 5, 6
Customer Input 4
10107
—
1
Active on Alarm
1, 2, 3, 4, 5, 6
Dig Scroll Comp Discharge Temp Sensor Issue 1
10108
—
1
Active on Alarm
1, 2, 3, 4, 5, 6
Dig Scroll Comp Discharge Temp Sensor Issue 2
10109
—
1
Active on Alarm
1, 2, 3, 4, 5, 6
Supply Air Over Temperature
10209
—
1
Active on Alarm
1, 2, 3, 4, 5, 6
Supply Air Under Temperature
10210
—
1
Active on Alarm
1, 2, 3, 4, 5, 6
Ambient Air Sensor Issue
10211
—
1
Active on Alarm
2, 3, 4, 5, 6
Compressor Short Cycle 1
10212
—
1
Active on Alarm
1, 2, 3, 4, 5, 6
Compressor Short Cycle 2
10213
—
1
Active on Alarm
1, 2, 3, 4, 5, 6
Ext Free Cooling Lockout
10214
—
1
Active on Alarm
1, 2, 3, 4, 5, 6
Reheater Over Temperature
10215
—
1
Active on Alarm
1, 2, 3, 4, 5, 6
Humidifier Cylinder Worn
10216
—
1
Active on Alarm
1, 2, 3, 4, 5, 6
Humidifier Under Current
10217
—
1
Active on Alarm
1, 2, 3, 4, 5, 6
Fan Issue
10218
—
1
Active on Alarm
1, 2, 3, 4, 5, 6
Condenser TVSS Issue
10219
—
1
Active on Alarm
1, 2, 3, 4, 5, 6
Condenser VFD Issue
10220
—
1
Active on Alarm
1, 2, 3, 4, 5, 6
Condenser Issue 1
10221
—
1
Active on Alarm
1, 2, 3, 4, 5, 6
Condenser Issue 2
10222
—
1
Active on Alarm
1, 2, 3, 4, 5, 6
BMS Communications Timeout
10223
—
1
Active on Alarm
1, 2, 3, 4, 5, 6
Digital Output Board Not Detected 1
10224
—
1
Active on Alarm
1, 2, 3, 4, 5, 6
Digital Output Board Not Detected 2
10225
—
1
Active on Alarm
1, 2, 3, 4, 5, 6
Digital Output Board Not Detected 3
10226
—
1
Active on Alarm
1, 2, 3, 4, 5, 6
Table 6
Liebert Challenger 3000
™
, Liebert Challenger ITR
™
, Liebert CW
™
, Liebert Deluxe System/3
™
,
Liebert DS
™
, Liebert DSE
™
, Liebert HPM
™
, Liebert PeX
™
- Status and Coil (continued)
Controller
Liebert iCOM
®
v4
Liebert Products
Units with
Liebert iCOM
®
:
Liebert HPM
Units with Liebert iCOM Firmware
PA1.04.033.STD or later:
Liebert Challenger 3000
Liebert Challenger ITR
Liebert CW
Liebert Deluxe System/3
Liebert DS
Liebert DSE
Liebert PeX
Available Points
Data Label
Status
Coil
Number
of Bits
Notes / Units
Extra Notes