To configure Ethernet Port A, enter the following for auto-sensing mode: 
ethertype auto
or to configure a speed and duplex, use the following command:
ethertype <10|100> <half|full>
To display the current configuration and status of the Ethernet ports, enter: 
status
For example, to configure a full-duplex 100Mbps link, enter:
ethertype 100 full
Step three: Assign an IP address to the MCU (optional)
The default setting for the MCU is to use DHCP to obtain an IP address. You can 
assign a static IP address if you prefer or if a DHCP server is not available.
If you want the IP address of the MCU to be assigned by your DHCP server, omit this 
step.
To assign a static IP address, use the following command: 
static <IP address> <netmask> <default gateway address> 
<DNS server address> 
For example, to assign an address of 192.168.1.2 where the default gateway is at 
192.168.1.1, enter:
static 192.168.1.2 255.255.255.0 192.168.1.1 0.0.0.0
To return to using DHCP after setting a static address, use the following 
command:
dhcp
Step four: Discover the IP address of the MCU
1
To display the current status of the IP address, enter: 
status
If you have DHCP enabled on your network and you are allowing the MCU to 
acquire its address using DHCP, the IP address that has been acquired by 
Ethernet Port A will be shown; if you have assigned a static IP address, that is the 
address that will be shown.
2
Make a note of the IP address. You will use this to access the web interface of the 
unit.
To establish a 1000Mbps connection, both ends of the link must be 
configured as auto-sensing.
If you do not have a DNS server, use 0.0.0.0 as the DNS server IP 
address.