Roberts Gorden BH15 Manuel D’Utilisation

Page de 25
NSTALLATION
 O
PERATION
 
AND
 S
ERVICE
 M
ANUAL
10 
4.9 
Burner Specifications
Figure 16: 
BLACKHEAT® Linear and U-Tube
Fan
Damper
Swirler*
Plan View
Reflector
171 mm
End View
Internal Swirler*
Side View
273 mm
317 mm
Heat Exchanger Length
Heat Exchanger Length
Fan Tube
U-Tube
Plan View
Fan
Burner Tube
Burner Tube
100 mm
100 mm
Damper
*Swirler must always be located in Fan Tube
4.9.1 Burner Air Plate 
      BH15 BH20 BH25 BH30 BH35 BH40 BH45 BH50 
Marking 071300+ 20 15 12 06 07 09 11 10 
4.9.2 Jet Marking 
BH15 BH20 BH25 BH30 BH35 BH40 BH45 BH50 
Natural 
   #30 3.8 mm #19 4.7 mm #9 #3 #1 D 
Propane/Butane  #46 2.3 mm #37 #33 3.1 mm 3.3 mm #29 #26 
 
4.9.3 Gas Consumption 
  BH15 BH20      BH25 BH30      BH35 BH40 BH45       BH50 
Natural 
             [MJ/hr] 54 72 90 110 125 138 162  180 
ULPG   MJ/hr as Natural Gas. Approximate kg/h consumption as below for reference only.
[kg/h]
[1.07]
 
[1.43]
 
[1.79]
 
[2.15]
[2.50]
 
[2.86]
 
[3.22]
 
[3.58]
 
 
4.9.4 Governor Pressure 
BH15 BH20 BH25 BH30 BH35 BH40 BH45 BH50 
ULPG                         All Models 2.60 kPa 