Manuel D’UtilisationTable des matièresContents3Before You Begin91.1 Overview91.2 Safety91.3 Determining transmitter information91.4 PROFIBUS-DP functionality101.5 Determining version information101.6 Communication tools111.7 Planning the configuration111.8 Pre-configuration worksheet131.9 Flowmeter documentation141.10 Micro Motion customer service14Flowmeter Startup152.1 Overview152.2 Setting the node address152.3 Bringing the transmitter online15Using the Transmitter User Interface173.1 Overview173.2 User interface without or with display173.3 Removing and replacing the transmitter housing cover193.4 Using the optical switches193.5 Using the display203.5.1 Display language203.5.2 Viewing process variables203.5.3 Using display menus213.5.4 Display password213.5.5 Entering floating-point values with the display21Connecting with ProLink II or Pocket ProLink Software254.1 Overview254.2 Requirements254.3 Configuration upload/download264.4 Connecting from a PC to a Model 2400S DP transmitter264.4.1 Connection options264.4.2 Service port connection parameters264.4.3 Making the connection274.5 ProLink II language28Using a PROFIBUS Host295.1 Overview295.2 Support files295.3 Connecting to the Model 2400S DP transmitter295.4 Using the GSD305.5 Using the EDD315.6 Using PROFIBUS bus parameters31Required Transmitter Configuration336.1 Overview336.2 Characterizing the flowmeter336.2.1 When to characterize336.2.2 Characterization parameters336.2.3 How to characterize356.3 Configuring the measurement units366.3.1 Mass flow units386.3.2 Volume flow units386.3.3 Density units406.3.4 Temperature units416.3.5 Pressure units41Using the Transmitter437.1 Overview437.2 Using the I&M functions437.3 Recording process variables447.4 Viewing process variables447.4.1 With the display447.4.2 With ProLink II457.4.3 With a PROFIBUS host and the EDD457.4.4 With a PROFIBUS host and the GSD457.4.5 With PROFIBUS bus parameters467.5 Using the LEDs467.5.1 Using the network LED467.5.2 Using the software address LED467.6 Viewing transmitter status477.6.1 Using the status LED477.6.2 Using ProLink II477.6.3 Using a PROFIBUS host and the EDD477.6.4 Using PROFIBUS bus parameters477.7 Handling status alarms487.7.1 Using the display497.7.2 Using ProLink II507.7.3 Using a PROFIBUS host with the EDD517.7.4 Using PROFIBUS bus parameters527.8 Using the totalizers and inventories537.8.1 Viewing current totals for totalizers and inventories537.8.2 Controlling totalizers and inventories55Optional Configuration598.1 Overview598.2 Configuring volume flow measurement for gas608.2.1 Using ProLink II618.2.2 Using a PROFIBUS host with the EDD628.2.3 Using PROFIBUS bus parameters628.3 Configuring cutoffs628.3.1 Cutoffs and volume flow638.4 Configuring the damping values638.4.1 Damping and volume measurement648.5 Configuring the flow direction parameter648.6 Configuring events658.6.1 Defining events658.6.2 Checking and reporting event status688.6.3 Changing event setpoints from the display698.7 Configuring slug flow limits and duration698.8 Configuring status alarm severity708.9 Configuring the display738.9.1 Update period738.9.2 Language738.9.3 Display variables and display precision748.9.4 LCD panel backlight758.9.5 Display functions758.10 Configuring digital communications768.10.1 PROFIBUS-DP node address768.10.2 IrDA port usage778.10.3 Modbus address788.10.4 Modbus ASCII support788.10.5 Floating-point byte order788.10.6 Additional communications response delay798.10.7 Digital communications fault action798.10.8 Fault timeout808.11 Configuring device settings818.12 Configuring PROFIBUS I&M function values818.13 Configuring sensor parameters828.14 Configuring the petroleum measurement application828.14.1 About the petroleum measurement application828.14.2 Configuration procedure848.15 Configuring the enhanced density application858.15.1 About the enhanced density application858.15.2 Configuration procedure87Pressure Compensation and External Temperature Compensation899.1 Overview899.2 Pressure compensation899.2.1 Options899.2.2 Pressure correction factors899.2.3 Configuration909.3 External temperature compensation929.4 Obtaining external pressure and temperature data94Measurement Performance9510.1 Overview9510.2 Meter validation, meter verification, and calibration9510.2.1 Meter verification9510.2.2 Meter validation and meter factors9710.2.3 Calibration9710.2.4 Comparison and recommendations9810.3 Performing meter verification9910.3.1 Preparing for the meter verification test9910.3.2 Running the meter verification test, original version9910.3.3 Running Smart Meter Verification10410.3.4 Reading and interpreting meter verification test results11010.3.5 Setting up automatic or remote execution of the meter verification test11710.4 Performing meter validation11910.5 Performing zero calibration12010.5.1 Preparing for zero12110.5.2 Zero procedure12110.6 Performing density calibration12510.6.1 Preparing for density calibration12510.6.2 Density calibration procedures12610.7 Performing temperature calibration129Troubleshooting13111.1 Overview13111.2 Guide to troubleshooting topics13111.3 Micro Motion customer service13211.4 Transmitter does not operate13211.5 Transmitter does not communicate13211.6 Checking the communication device13211.7 Diagnosing wiring problems13311.7.1 Checking the power supply wiring13311.7.2 Checking PROFIBUS wiring13411.7.3 Checking grounding13411.8 Zero or calibration failure13411.9 Fault conditions13411.10 Simulation mode13511.11 Transmitter LEDs13611.12 Status alarms13611.13 Checking process variables14011.14 Checking slug flow14211.15 Checking the sensor tubes14311.16 Checking the flow measurement configuration14311.17 Checking the characterization14311.18 Checking the calibration14311.19 Restoring a working configuration14411.20 Checking the test points14411.20.1 Obtaining the test points14411.20.2 Evaluating the test points14411.20.3 Drive gain problems14511.20.4 Low pickoff voltage14511.21 Checking sensor circuitry146Default Values and Ranges151A.1 Overview151A.2 Most frequently used defaults and ranges151Transmitter Components155B.1 Overview155B.2 Transmitter components155B.3 Terminals and connectors156Menu Flowcharts - Model 2400S DP Transmitters157C.1 Overview157C.2 Version information157C.3 ProLink II menu flowcharts158C.4 EDD menu flowcharts161C.5 Display menu flowcharts168PROFIBUS Bus Parameters173D.1 Overview173D.2 PROFIBUS-DP data types and data type codes174D.3 Measurement block (Slot 1)174D.4 Calibration block (Slot 2)176D.5 Diagnostic block (Slot 3)178D.6 Device Information block (Slot 4)186D.7 Local Display block (Slot 5)187D.8 API block (Slot 6)189D.9 Enhanced Density block (Slot 7)189D.10 I&M functions (Slot 0)193D.11 Totalizer and inventory measurement unit codes193D.12 Process variable codes194D.13 Alarm index codes195Display Codes and Abbreviations197E.1 Overview197E.2 Codes and abbreviations197Index201Taille: 2,3 MoPages: 208Language: EnglishOuvrir le manuel