Introduction
Vented wall furnace is shipped ready to install in a 2" x 4"  stud wall, 
with studs 16" (406mm) center to center.  Always consult your local 
Building Department regarding regulations, codes or ordinances 
which apply to the installation of a  vented wall furnace.
Instructions to Installer
1.  Installer must leave instruction manual with owner after instal-
lation.
2.  Installer must have owner fill out and mail warranty card sup-
plied with furnace.
3.  Installer should show owner how to start and operate furnace 
and thermostat.
Warning:
Any change to this furnace or its control can be dangerous.  
This is a heating appliance and any panel, door or guard 
removed for servicing an appliance must be replaced prior 
to operating the appliance.
General Information
This series is design certified in accordance with American National 
Standard / CSA Standard Z21.86 and CSA 2.32 by the Canadian 
Standards Association,  as  a  Vented  Wall  Furnace  and  must  be 
installed according to these instructions.
Any alteration of the original design, installed other than as 
shown in these instructions or use with a type of gas not shown 
on the rating plate is the responsibility of the person and com-
pany making the change.
Important
All correspondence should refer to complete Model No., Serial 
No. and type of gas.
Notice:  During initial firing of this furnace, its paint will bake 
out and smoke will occur.  To prevent triggering of smoke alarms, 
ventilate the room in which the furnace is installed.
Installation in Residential Garages
Gas utilization equipment in residential garages shall be installed 
so that all burners and burner ignition devices are located not less 
than 18" (457mm) above the floor.
Such equipment shall be located, or protected, so it is not subject 
to physical damage by a moving vehicle.  
Qualified Installing Agency
Installation and replacement of gas piping, gas utilization equipment 
or  accessories  and  repair  and  servicing  of  equipment  shall  be 
performed only by a  qualified agency.  The term "qualified agency" 
means any individual, firm, corporation or company which either in 
person or through a representative is engaged in and is responsible 
for  (a)  the  installation  or  replacement  of  gas  piping  or  (b)  the 
connection, installation, repair or servicing of equipment, who is 
experienced in such work, familiar with all precautions required 
and has complied with all the requirements of the authority having 
jurisdiction.
State  of  Massachusetts:  The  installation  must  be  made  by 
a  licensed  plumber  or  gas  fitter  in  the  Commonwealth  of 
Massachusetts.
The installation must conform to local codes  or, in  the absence of 
local codes, with the  National Fuel Gas Code ANSI  Z223.1/NFPA 
54* Natural Gas and Propane Installation Code, CSA B149.1.
*Available from the American National Standards Institute, Inc., 11 West 42nd St., 
New York, N.Y. 10036.
High Altitudes
For  altitudes/elevations  above  2,000  feet  (610m),  input  ratings 
should be reduced at the rate of 4 percent for each 1,000 (305m) 
feet above sea level. Canadian High Altitudes for locations having 
an elevation above mean sea level between 2,000 feet (610m) and 
4,500 feet (1370m), the manifold pressure is to be decreased from 
3.5" w.c. (.871kPa) to 3.0" w.c. (.747kPa) for Natural Gas and from 
10.0" w.c. (2.49kPa) to 8.0" w.c. (1.992kPa) for Propane Gas.
INTRODUCTION
SPECIFICATIONS
Model
GWT-25
GWT-35
Input BTU/HR (KW/H)
25,000 (7.3)
35,000 (10.3)
Height
66 1/8" (1679mm)
66 1/8" (1679mm)
Width
16" (406mm)
16" (406mm)
Depth
6" (152mm)
6" (152mm)
Gas Inlet Pipe
1/2"
1/2"
Vent Pipe Type B Oval
4" (102mm)
4" (102mm)
Accessories
Blower Kit
GWTB-2
GWTB-2
Rear Register Kit
GWTR-1
GWTR-1
Out-of-the-Wall Kit
GWTW-2
GWTW-2
Attention: When the GWTW-2, Out-of-the-Wall kit is used the GWTR-1 Rear Register kit 
cannot be used.