Honeywell perfect climate comfort center control system Manuale Utente

Pagina di 44
35
68-0173—3
Adaptive Intelligent Recovery™ Operation
Adaptive Intelligent Recovery™ operation is Honeywell’s 
trademark for the way the Comfort Center™ system controls 
the heating and cooling equipment during recovery from an 
energy savings setting (SLEEP, LEAVE) to a comfort setting 
(WAKE, RETURN). This provides additional energy savings.
The advantages are:
• Comfort setting is achieved at the programmed time and 
maintained regardless of the weather conditions; 
occupants come home and wake up in comfort.
• Drafts from low temperature discharge air are minimized 
during occupied periods.
• Comfort Center™ control system automatically uses the 
more economical first stage of the heat pump as the 
primary heat source during the heat mode recovery, 
avoiding the use of the expensive second-stage of heating 
(auxiliary heat).
• Comfort and energy savings can be achieved in both 
heating and cooling.
• Reduces heat pump and air conditioner compressor 
cycling, extending equipment life.
Adaptive Intelligent Recovery™ operation is used during 
recovery from energy savings. It is bypassed when configured 
for conventional recovery but not when setpoint is temporarily 
changed. When Adaptive Intelligent Recovery™ operation is 
bypassed, the system operates the stages of equipment like a 
conventional control.
PC8900A Used with W8900A,C Remote Module 
(Conventional Heat/Cool Applications)
During recovery, the Comfort Center™ program calculates the 
amount of time required to bring the living space from the 
current room temperature (achieved in the energy savings 
mode) to the comfort temperature programmed for the 
comfort mode. When that time is reached, the present 
setpoint changes from the energy savings setpoint to the 
comfort setpoint. The result is that the living space 
temperature is at the programmed setpoint at the 
programmed time, providing the occupants with the maximum 
comfort. See Fig. 33. 
PC8900A Used with W8900B Remote Module 
(Heat Pump Applications)
During recovery, the Comfort Center™ program works to 
achieve comfort in the same manner, by calculating the 
amount of time required to bring the living space from the 
current room temperature to the comfort temperature 
programmed for the comfort mode. The living space 
temperature reaches the programmed setpoint at the 
programmed time so the occupants achieve maximum 
comfort.
Another way the Comfort Center™ program minimizes 
auxiliary heat usage is by having two recovery ramps: one for 
stage-one compressor and one for auxiliary heat.
Fig. 33. Heat pump Adaptive Intelligent Recovery™ ramp.
Operation
Seasonal weather changes allow the Adaptive Intelligent 
Recovery™ ramp to change on a daily basis and still meet the 
comfort needs of the occupants. In the fall, heating loads are 
light so recovery begins very late in the energy savings 
period. As fall changes to winter, loads increase and the 
Adaptive Intelligent Recovery™ ramp shifts so recovery 
begins earlier each day. Conversely, recovery begins later 
each day as heating loads decrease from winter to spring. 
See Fig. 34 and 35.
Fig. 34. Fall to winter Adaptive 
Intelligent Recovery™ ramp.
Fig. 35. Winter to spring Adaptive 
Intelligent Recovery™ ramp.
Energy Savings Period
In mild to moderate weather, the PC8900A calls on the heat 
pump only when the sensed temperature falls below the 
setpoint. Under mild to moderate conditions, the more 
costly auxiliary heat is not needed. In severe weather, the 
heat pump cycles only when the sensed temperature falls 
below setpoint and auxiliary heat cycles continuously. See 
Fig. 36 through 38.
WAKE
COMPRESSOR SETPOINT
AUXILIARY HEAT SETPOINT
ROOM TEMPERATURE
M6406A
70 F
60 F
SLEEP
HEATING MODE
WAKE
SETPOINT
TEMPERATURE
ACTUAL
TEMPERATURE
M6185A
70 F
60 F
SLEEP
WAKE
SETPOINT
TEMPERATURE
ACTUAL
TEMPERATURE
M6186