VENT INSTALLATION 
TERMINATION CLEARANCES FOR BUILDINGS WITH COMBUSTIBLE 
AND NONCOMBUSTIBLE EXTERIORS 
Figure 9 - Allowable Venting Chart 
HOW TO USE THE VENT GRAPH
The Vent Graph should be read in conjunction with the following 
vent installation instructions to determine the relationship between 
the vertical and horizontal dimensions of the vent system.
1.    Determine the height of the center of the horizontal vent pipe exit-
ing through the outer wall. Using this dimension on the Sidewall 
Vent Graph below, locate the point intersecting with the slanted 
graph line.
2.    From the point of this intersection, draw a vertical line to the 
bottom of the graph.
3.    Select  the  indicated  dimension,  and  position  the  fireplace  in 
accordance with same.
      
Example: If the vertical dimension from the floor of the 
fireplace is 11' (3.4m) the horizontal run to the face of the 
outer wall must not exceed 14' (4.3m).
      Example: If the vertical dimension from the floor of the unit 
is 7’ (2.14m), the horizontal 
wall must not exceed 
' (2.14m).
run to the face of the outer 
Sidewall Vent Graph showing the relationship between vertical and 
horizontal dimensions for a Direct Vent flue system.
Figure 10 - Rear Wall Venting Graph
Horizontal Dimension (Ft) From the Outside of 
Termination to the Back of the Fireplace
V
ertical Dimension
 (
Ft) 
From the Floor of Unit to the Center of 
the Horizontal V
ent Pipe
Dimensions in Feet