Mastic 91P Manuale Utente

Pagina di 42
18                                                                                                                                                       
L100001                                                                                                                                                                            
19
HO
T
HO
T
VENT INSTALLATION 
4.  Apply a bead of non-hardening mastic around the outside 
edge of vent cap. Position the vent cap in the center of hole 
on the exterior wall with the 
arrow up
 on the vent cap
.
Insure proper clearance of 1" to combustibles is main-
tained. Attach the vent cap with four wood screws
 supplied.
See Figure 14.
NOTE: Replace the wood screws with appropriate fasteners 
for stucco, brick, concrete, or other types of siding. 
For vinyl siding, stucco, or wood exterior use vinyl siding stand-
offs between vent cap and exterior wall. The vinyl siding standoff 
prevents excessive heat from melting the vinyl siding material. Bolt 
the vent cap to the standoff. Apply non-hardening mastic around 
outside edge of the standoff instead of the vent cap assembly. Use 
wood screws provided to attach the standoff. See Figure 15.
5.  Slide the wall thimble over the vent pipe before connecting 
the horizontal run to the vent cap. See Figure 16.
6.  Carefully  move  the  fireplace  with  vent  assembly  attached 
toward the wall and insert the vent pipe into the horizontal 
termination. The pipe overlap should be a minimum of 1
1
/
4
". 
Apply silicone to the outer pipe connection. Fasten all vent 
connections with screws provided.
7.  Slide the wall thimble against the interior wall surface and 
attach with srews. See Figure 16. 
Figure 14 - Installing Horizontal Vent Cap 
REAR WALL VENT INSTALLATION (continued)
Figure 15 - Installing Vinyl Siding Standoff 
Apply Mastic 
to All Four 
Sides 
Vent Cap
Wood 
Screw
Cut Vinyl Siding Away to 
Fit Standoff 
Wood Screw
Vent Cap
Bolt
Apply Mastic to All 
Four Sides 
Nut
Standoff 
Figure 16 - Connecting Vent Cap with Horizontal Vent Pipe 
Interior Wall 
Surface 
Decorative 
Wall Thimble 
Horizontal 
Vent Pipe 
Screw
Vent Cap 
(Horizontal 
Termination)
Deflecting Shield 
Do not recess vent termination into any wall. 
This will cause a fire hazard. 
WARNING