5.4.3  Example of incorrect resonator connection 
Figure 5-9 shows examples of incorrect resonator connection. 
 
Figure 5-9.  Examples of Incorrect Resonator Connection (1/2) 
(a)  Too long wiring 
(b)  Crossed signal line 
V
SS
X1
X2
 
V
SS
X1
X2
PORTn
(n = 0 to 3, 5)
 
(c)  Wiring near high fluctuating current 
(d)  Current flowing through ground line of oscillator 
(potential at points A, B, and C fluctuates) 
 
V
SS
X1
X2
High current
 
V
SS
X1
A
B
C
P
mn
V
DD
High current
X2
 
 
Remark  When using the subsystem clock, read X1 and X2 as XT1 and XT2, respectively, and connect a resistor 