Blade ICE G8124-E Manuale Utente

Pagina di 388
BLADEOS 6.5.2 Application Guide
BMD00220, October 2010
Chapter 14: FCoE and CEE  

  201
Global Configuration
PFC requires CEE to be turned on (
). When CEE is turned 
on, standard flow control is disabled on all ports, and PFC is enabled on all ports for 802.1p priority 
value 3. While CEE is turned on, PFC cannot be disabled for priority value 3. This default is chosen 
because priority value 3 is commonly used to identify FCoE traffic in a CEE environment and must 
be guaranteed lossless behavior. PFC is disabled for all other priority values by default, but can be 
enabled for one additional priority value.

Global PFC configuration is preferable in networks that implement end-to-end CEE devices. 
For example, if all ports are involved with FCoE and can use the same SAN and LAN priority 
value configuration with the same PFC settings, global configuration is easy and efficient.

Global PFC configuration can also be used in some mixed environments where traffic with 
PFC-enabled priority values occurs only on ports connected to CEE devices, and not on any 
ports connected to non-CEE devices. In such cases, PFC can be configured globally on specific 
priority values even though not all ports make use them.

PFC is not restricted to CEE and FCoE networks. In any LAN where traffic is separated into 
different priorities, PFC can be enabled on priority values for loss-sensitive traffic. If all ports 
have the same priority definitions and utilize the same PFC strategy, PFC can be globally 
configured.
Note – 
When using global PFC configuration in conjunction with the ETS feature (see 
), ensure that only pause-tolerant traffic (such as lossless 
FCoE traffic) is assigned priority values where PFC is enabled. Pausing other types of traffic can 
have adverse effects on LAN applications that expect uninterrupted traffic flow and tolerate 
dropping packets during congestion.