Blade ICE G8124-E Manuale Utente

Pagina di 388
BLADEOS 6.5.2 Application Guide
202  

  Chapter 14: FCoE and CEE
BMD00220, October 2010
PFC Configuration Example
Note – 
DCBX may be configured to permit sharing or learning PFC configuration with or from 
external devices. This example assumes that PFC configuration is being performed manually. See 
 for more information on DCBX.
This example is consistent with the network shown in 
. In this example, the 
following topology is used.
In this example, PFC is to facilitate lossless traffic handling for FCoE (priority value 3) and a 
business-critical LAN application (priority value 4).
Assuming that CEE is off (the G8124 default), the example topology shown in 
 can be 
configured using the following commands:
1.
Turn CEE on.
Note – 
Turning CEE on will automatically change some 802.1p QoS and 802.3x standard flow 
control settings and menus (see 
).
Table 18   
Port-Based PFC Configuration
Switch
Port
802.1p
Priority
Usage
PFC
Setting
1
0-2
LAN
Disabled
4
Business-critical LAN
Enabled
others
(not used)
Disabled
 2
3
FCoE (to FCF bridge)
Enabled
others
(not used)
Disabled
3
3
FCoE
Enabled
others
(not used)
Disabled
4
0-2
LAN
Disabled
4
Business-critical LAN
Enabled
others
(not used)
Disabled
RS G8124(config)# cee enable