Blade ICE G8124-E Manuale Utente

Pagina di 388
BLADEOS 6.5.2 Application Guide
BMD00220, October 2010
Chapter 14: FCoE and CEE  

  203
2.
Enable PFC for the FCoE traffic.
Note – 
PFC is enabled on priority 3 by default. If using the defaults, the manual configuration 
commands shown in this step are not necessary.
3.
Enable PFC for the business-critical LAN application:
4.
Save the configuration.
RS G8124(config)# cee global pfc priority 3 enable
(Enable on FCoE priority)
RS G8124(config)# cee global pfc priority 3 description "FCoE"
(Optional description)
RS G8124(config)# cee global pfc priority 4 enable
(Enable on LAN priority)
RS G8124(config)# cee global pfc priority 4 description "Critical LAN"
(Optional description)