<esmode>
The errored seconds alarm setting. Type 
enable
 or 
disable
.
<uas>
The unavailable seconds threshold. When the number of unavailable seconds in the current 
15-minute data collection interval exceeds the specified threshold, the UAS alarm is 
activated. Unavailable seconds are seconds during which the SDSL frame loop is not 
synchronized. A typical unavailable seconds threshold value is 60.
<uasmode>
The unavailable seconds alarm setting. Type 
enable
 or 
disable
.
Example
::alarm=> new enable 6 enable 17 enable 60 enable
Displaying SDSL Frame Alarm Profiles
From the 
::alarm=>
 prompt, type the show command in the following format then press 
.
show [<index>]
Parameter
[<index>]
The SDSL frame alarm profile table index number of the profile you want to display. 
Omitting this parameter displays the entire SDSL frame alarm profile table.
Examples
::alarm=> show 1
::alarm=> show