Lucent Technologies P332MF Manuale Utente

Pagina di 134
Cajun P332MF User’s Guide
113
Installing the Expansion Sub-module in the Cajun P330
1
Remove the blanking plate or other sub-module (if installed).
2
Insert the sub-module gently into the slot, ensuring that the Printed Circuit 
Board (PCB) is aligned with the guide rails.
The PCB not the metal base plate fits into the guide rail.
3
Press the sub-module in firmly until it is completely inserted into the 
Cajun P330.
4
Gently tighten the two screws on the front panel of the expansion sub-module 
by turning the screws.
Note:  The expansion sub-modules contain components sensitive to electrostatic 
discharge. Do not touch the circuit board unless instructed to do so.
Removing an Existing Expansion Sub-module
1
Loosen the screws by turning the knobs.
2
Grasp the two knobs one near each side of the front panel, and pull gently but 
firmly towards yourself.
3
Insert another expansion sub-module or the blanking plate.
Note:  The Cajun P330 switch must not be operated with the expansion slot open; 
the expansion sub-module should be covered with the supplied blanking plate if 
necessary.
Note:  X330GT2 sub-modules are hot swapable and can be inserted or removed in 
an operating base unit.
Cabling 
A Category 5 copper cable with RJ-45 termination should be used. You should use 
all eight wires in the cable.
The maximum copper cable length connected to a 1000Base-T port is 100 m 
(328 ft.)