Hardware and Connectivity 50
Powering up your IOLAN
Wiring up a DHV unit
Terminal # Description
Usage
1
Normally Open Normally Open is a fail-safe relay connection. Use this with the
Common terminal to act as switch contacts that remain open when
the unit is powered off or in a failure state.
2
Common
Common is a fail-safe relay connection. Use this terminal in
conjunction with the Normally Open or Normally Closed terminals.
3
Normally
Closed
Closed
Normally Closed is a fail-safe relay connection. Use this with the
Common terminal to act as switch contacts that remain closed
Common terminal to act as switch contacts that remain closed
when the unit is powered off or in a failure state.
4
Chassis Ground Chassis Ground must be connected to "Equipment Ground" for DC
installations or "Safety Ground" for AC installations.
5
+ / L (source 1) + / L (Source 1) is connected to the positive (+) input for DC
sources or to the Live input for AC sources. Use with partner
terminal -/N(Source 1).
6
- / N(source 1)
- / N (Source 1) is connected to the negative (-) input for DC
sources or to the Neutral input for AC sources. Use with partner
terminal +/L(Source 1).
terminal +/L(Source 1).
7
+ / L (source 2) + / L (Source 2) is connected to the positive (+) input for DC
sources or to the Live input for AC sources. Use with partner
terminal -/N(Source 2).
8
- / N(source 2)
- / N (Source 2) is connected to the negative (-) input for DC
sources or to the Neutral input for AC sources. Use with partner
sources or to the Neutral input for AC sources. Use with partner
terminal +/L(Source 2).
E
Earth Ground
Earth Ground is a connection to the chassis that can be used for
earth bonding.
earth bonding.