Hardware and Connectivity  50
Powering up your IOLAN
Wiring up a DHV unit
Terminal # Description
Usage
1
Normally Open Normally Open is a fail-safe relay connection. Use this with the 
Common terminal to act as switch contacts that remain open when 
the unit is powered off or in a failure state.
2
Common
Common is a fail-safe relay connection. Use this terminal in 
conjunction with the Normally Open or Normally Closed terminals.
3
Normally 
Closed
Normally Closed is a fail-safe relay connection. Use this with the 
Common terminal to act as switch contacts that remain closed 
when the unit is powered off or in a failure state.
4
Chassis Ground Chassis Ground must be connected to "Equipment Ground" for DC 
installations or "Safety Ground" for AC installations.
5
+ / L (source 1) + / L (Source 1) is connected to the positive (+) input for DC 
sources or to the Live input for AC sources. Use with partner 
terminal -/N(Source 1).
6
- / N(source 1)
- / N (Source 1) is connected to the negative (-) input for DC 
sources or to the Neutral input for AC sources. Use with partner 
terminal +/L(Source 1).
7
+ / L (source 2) + / L (Source 2) is connected to the positive (+) input for DC 
sources or to the Live input for AC sources. Use with partner 
terminal -/N(Source 2).
8
- / N(source 2)
- / N (Source 2) is connected to the negative (-) input for DC 
sources or to the Neutral input for AC sources. Use with partner 
terminal +/L(Source 2).
E
Earth Ground
Earth Ground is a connection to the chassis that can be used for 
earth bonding.