Black Box LES1216A-R2 Manuale Utente

Pagina di 286
 
 
If you want to add the new host as a managed device, make sure you use the current total number of 
managed devices + 1, for the new device number.  
To get the current number of managed devices: 
# config -g config.devices.total 
Assuming we already have one managed device, our new device will be device 2. Issue the following 
commands: 
# config -s config. devices.device2.connections.connection1.name=192.168.3.10 
# config -s config. devices.device2.connections.connection1.type=Host 
# config -s config. devices.device2.name=OfficePC 
# config -s config. devices.device2.description=MyPC 
# config -s config.devices.total=2 
The following command will synchronize the live system with the new configuration: 
# config -hosts 
14.7  Trusted Networks 
You can further restrict remote access to serial ports based on the source IP address. To configure this 
via the command line, you need to do the following: 
Determine the total number of existing trusted network rules. If you have no existing rules, you can 
assume this is 0. 
# config -g config.portaccess.total 
This command should display config.portaccess.total 1  
Note that if you see config.portaccess.total this means you have 0 rules configured. 
Your new rule will be the existing total plus 1. So if the previous command gave you 0, then you start 
with rule number 1. If you already have 1 rule your new rule will be number 2, etc. 
If you want to restrict access to serial port 5 to computers from a single class C network (192.168.5.0 for 
example), you need to issue the following commands (assuming you have a previous rule in place). 
Add a trusted network: 
# config -s config.portaccess.rule2.address=192.168.5.0 
# config -s "config.portaccess.rule2.description=foo bar" 
# config -s config.portaccess.rule2.netmask=255.255.255.0 
# config -s config.portaccess.rule2.port5=on 
# config -s config.portaccess.total=2 
The following command will synchronize the live system with the new configuration: 
# config -r serialconfig 
14.8  Cascaded Ports 
 
To add a new slave device with the following settings: 
IP address/DNS name   
192.168.0.153 
Description 
 
 
Console in office 42 
Label   
 
 
les1116-5 
Number of ports 
 
16 
The following commands must be issued: 
_____________________________________________________________________ 
 
 
724-746-5500 | blackbox.com
 
 Page 223