Insys MoRoS ISDN 1.1.1 11-02-06-02-01.005 Manuale Utente

Codici prodotto
11-02-06-02-01.005
Pagina di 46
Functions 
MoRoS Modem/ISDN 
32
 
 
June 06
 
continent (e.g. Europe/Berlin). For the latter, the country-specific time settings will be 
considered, such as the daylight savings time in Germany. 
The set time for this time zone will be accepted after clicking “OK”. 
 
 
Two reset types are available: 
¾
  Hard reset 
o  by interrupting the supply voltage, or 
o  by pressing the reset key for more than 3 seconds. 
 
¾
  Soft reset 
o  by pressing the reset key for no longer than 1 second, or 
o  by reset via the configuration interface.  
“OK” will initiate a restart or the loading of the basic settings plus restart. After a restart, 
it will take about 25 seconds until the MoRoS is again ready for operation. During the 
restart, the “Status” LED on the front panel of the housing lights up red. The MoRoS be 
ready for operation after the LED goes out. After the basic settings have been loaded, it 
takes about one minute until the MoRoS is ready for operation. 
   The loading of the basic settings results in all settings being reset to the 
factory defaults. This also concerns the user name and the password for the 
configuration interface. The IP address and the network mask are also reset 
to the factory defaults (see Chapter 6).
 
Resetting to the basic settings should be avoided when performing a remote 
configuration. The loading of the basic settings also means that Dial-Out and Dial-In are 
deactivated. It will not be possible afterwards to remotely Dial-In into the MoRoS. The 
configuration can then only be performed via a local connection! 
The MoRoS can also be restarted by pushing the reset key on the front panel of the 
housing for a short time (maximum of 1 second). 
The rewriting of the factory settings can also take place via the reset key. Press the reset 
key three times for a short time within 2 seconds. Afterwards, the LED “Status” lights up 
red.