Problem
Possible Cause
Remedy
e) Compressor
1. Loose connections.
1. Tighten.
2. Motor winding opened 
or grounded.
2. Replace.
3. Compressor locked 
and motor protector 
tripped.
3. Replace compressor.
f) Power Supply
1. Circuit ampacity too 
low.
1. Install a larger-sized 
circuit.
[5] Gear motor and 
compressor start, but 
no ice is produced.
a) Refrigerant Line
1. Gas leaks.
1. Check for leaks with a leak 
detector. Replace drier and 
charge with refrigerant. 
Refrigerant charge is 
marked on nameplate or 
rating label.
2. Refrigerant line 
clogged.
2. Replace the clogged 
component.
2. Low Ice Production
Problem
Possible Cause
Remedy
[1] Low ice production.
a)Refrigerant Line
1. Gas leaks.
1. See "2. [5] a) Refrigerant 
Line."
2. Refrigerant line 
clogged.
2. Replace the clogged 
component.
3. Overcharged.
3. Recharge.
b)High-Side Pressure Too 
High
1. Dirty air filter or 
condenser. 
1. Clean.
2. Ambient or condenser 
water temperature too 
warm. 
2. Reduce temperature.
3. Condenser water 
pressure too low or off. 
[water-cooled model 
only]
3. Check and get recom-
mended pressure.
4. Fan, slow rpm.
4. See "3. [1] a) Fan Motor".
5. Water regulating valve 
clogged. [water-cooled 
model only]
5. Clean.
c) Expansion Valve (not 
adjustable)
1. Low-side pressure too 
low.
1. Replace.
2. Low-side pressure too 
high.
2. See if expansion valve 
bulb is mounted properly, 
and replace the valve if 
necessary.
3. Other