American Standard 2002 Manuale Utente

Pagina di 6
7 3 0 5 2 9 - 1 0 0   R e v .   M
CHAMPION® FLUSHING SYSTEM TEN-YEAR WORRY-FREE™ LIMITED WARRANTY
For this warranty to become effective, the accompanying warranty registration card and proof of purchase must be completed and 
returned to the address on the warranty registration card within 30 days of purchase.
If inspection of this American Standard plumbing product, inclusive of china and all mechanical components, within ten years after its 
initial purchase, confirms that it is defective in materials or workmanship, American Standard will repair or, at its option, exchange the 
product for a similar model. 
This warranty does not apply to local building code compliance.  Since local building codes vary considerably, the purchaser of this 
product should check with a local building or plumbing contractor to insure local code compliance before installation.
This warranty shall be void if the product has been moved from its initial place of installation; if it has been subjected to faulty 
maintenance, abuse, misuse, accident or other damage; if it was not installed in accordance with American Standard's instructions; or if it 
has been modified in a manner inconsistent with the product as shipped by American Standard.
This warranty DOES NOT COVER any damage caused by the use of in-tank cleaners.
American Standard's option to repair or exchange the product under this warranty does not cover any labor or other costs of removal or 
installation,  nor shall American Standard be responsible for any other incidental or consequential damages attributable to a 
product defect or to the repair or exchange of a defective product, all of which are expressly excluded from this warranty.
 (Some 
states or provinces do not allow the exclusion or limitation of implied warranties, so this exclusion may not apply to you.)
This warranty gives you specific legal rights. You may have other statutory rights that vary from state to state or from province to 
province, in which case this warranty does not affect such statutory rights.
For service under this warranty, it is suggested that a claim be made through the contractor or dealer from or through whom the product 
was purchased, or that a service request (including a description of the product  model and of the defect) be sent  to the following address:
-   6   -
In the United States:
American Standard Inc.
P.O. Box 6820
Piscataway, New Jersey 08855
Attention: Director of  Consumer Affairs
For residents of the United States, warranty 
information may also be obtained by calling 
the following toll free number: (800) 442-1902
In Canada:
American Standard
2480 Stanfield Rd.  
Mississauga, Ontario 
Canada L4Y 1S2
Toll Free:  (800) 387-0369
In Mexico:
Customer Service Manager 
Ideal Standard, S.A. de C.V.
Via Morelos #330
Col. Santa Clara
Ecatepec 55540 Edo. Mexico
Does not flush
Poor or sluggish flush
Toilet leaks
Toilet does not shut off
a.  Water supply valve closed.
b.  Supply line blocked.
c.  Flush valve chain too loose or disconnected.
d.  Sand or debris lodged in water control.
a. Bowl water level too low.
b.  Supply valve partly closed.
c.  Partially clogged trapway and/or drain pipe and/or vent.
d.  Supply pressure too low.
e.  Flush valve chain too tight, pull rod not engaging.
a.  Poor supply line connection.
b.  Poor bowl to tank/floor connection.
a.  Flush valve seal leaking or deformed.
b.  Sand or debris lodged in water control.
a.  Open valve and allow water to fill tank.
b.  Shut off water supply, disconnect supply line and inspect all    
      
     gaskets and washers. Reassemble. Also, see Fluidmaster  
       
     maintenance. (see Step 14)
c.  Readjust chain length as required.
d.  Shut off water supply. Remove cap and clean as per Step 14.
a.  Check that refill tube is connected to water control and  
     
     inserted into tank overflow without being kinked or damaged.  
     
     (see Step 13a)
b.  Open supply valve fully. Be sure that proper supply tube size  
     
     is used.
c.  Remove obstruction. Consult a plumber if necessary.
d.  Normal supply pressure must be at least 20 psi.
e.  Readjust chain length as needed. Review Step 10.
a.  Review Step 9 of installation procedure.
b.  Review Step 4 through 7 of installation procedure.
a.  Clean debris from seal surface. Replace flush valve seal as  
     
     needed. (see Step 13)
b.  Shut off water supply. Remove cap and clean as per Step 14.
TROUBLESHOOTING GUIDE
PROBLEM
POSSIBLE CAUSE
CORRECTIVE ACTION
www.americanstandard-us.com
www.americanstandard.ca
www.americanstandard.com.mx