THERMOSTAT OPERATION 
Thermostat Installation 
1.  Unplug the unit and remove the back panel of the stove. 
2.  Locate the thermostat connect block, labeled J18, on the rear of the control 
board, near the bottom (See image below and pg. 43 of this manual for a 
control board diagram).  It will have a small wire “jumper” installed in it 
from the factory.  This jumper bypasses the thermostat and should be saved. 
3.  Loosen the two screws using a small slotted “jewelers” screwdriver and 
remove the “jumper.” 
4.  Insert the two thermostat wires in place of the “jumper” and retighten the 
screws. 
5.  Reinstall the back panel and mount the thermostat; the control board 
automatically reads the thermostat and your stove is now ready for 
thermostat operation. 
Connect 
thermostat 
wires here 
(J18)