REPLACING COMPONENTS 
Convection Blower 
1.  Before beginning any component 
replacement, be certain the unit is 
unplugged and thoroughly cooled 
down.  
2.  Remove the right side panel as 
previously detailed in this manual on 
Page. 32 in the “Exhaust Blower 
Cleaning” section. 
3.  Detach the convection blower from 
the wiring harness before loosening 
the four screws which secure it to the 
convection shroud of the stove. 
4.  After loosening and removing the 
four screws which hold the blower to 
the stove, remove the blower from 
the stove. 
5.  Installation of the new blower is 
performed in reverse of removal; 
remember to reconnect the new 
blower to the wiring harness before 
reinstalling the side panel. 
 
 
Combustion Blower 
1.  Before beginning any component 
replacement, be certain the unit is 
unplugged and thoroughly cooled 
down.  
2.  Remove the left side panel as 
previously detailed on pg. 32. 
3.  Disconnect the venting system from 
the exhaust blower, and disconnect 
the exhaust blower from the stove 
wiring harness.  Loosen and remove 
the thermal sensor screw on the top 
of the exhaust blower outlet using a 
5/16” wrench. 
4.  Loosen and remove all five screws 
which hold the exhaust blower to the 
exhaust blower tube.  Once the 
screws have been removed, the 
blower can be lifted up and out of the 
stove. 
5.  Reinstallation is the exact opposite 
of the steps above; however be 
certain to check the condition of the 
exhaust blower gasket and replace if 
necessary.