Desa KEROSENE HIGH PRESSURE PORTABLE FORCED AIR HEATERS Manuale Utente

Pagina di 24
www.desatech.com
110098-01F
2
SAFETY INFORMATION
IMPORTANT:  Read  this  owner’s 
manual carefully and completely 
before trying to assemble, operate 
or  service  this  heater.  Improper 
use of this heater can cause seri-
ous injury or death from burns, fire, 
explosion,  electrical  shock  and 
carbon monoxide poisoning.
 WARNING: This product con-
tains and/or generates chemicals 
known to the State of California 
to cause cancer or birth defects 
or other reproductive harm.
 DANGER: Carbon monoxide 
poisoning may lead to death!
Carbon  Monoxide  Poisoning:
  Early  signs  of 
carbon monoxide poisoning resemble the flu, with 
headaches, dizziness and/or nausea. If you have 
these signs, the heater may not be working properly. 
Get fresh air at once! Have heater serviced. Some 
people are more affected by carbon monoxide than 
others. These include pregnant women, persons 
with heart or lung disease or anemia, those under the 
influence of alcohol and those at high altitudes. 
Make certain you read and understand all warn-
ings. Keep this manual for reference. It is your 
guide to safe and proper operation of this heater. 
1.  Use only kerosene, #1#2 diesel/fuel oil, JET A 
or JP-8 fuels to avoid risk of fire or explosion. 
Never use gasoline, naphtha, paint thinners, 
alcohol or other highly flammable fuels.
2.  Fueling
a) Personnel  involved  with  fueling  shall  be 
qualified and thoroughly familiar with the 
manufacturerʼs instructions and applicable 
federal, state and local regulations regarding 
the safe fueling of heating units.
b) Only the type of fuel specified on the heaterʼs 
data plate shall be used.
c) All flame, including the pilot light, if any, 
shall be extinguished and the heater allowed 
to cool, prior to fueling.
d) During fueling, all fuel lines and fuel-line 
connections shall be inspected for leaks. Any 
leaks shall be repaired prior to returning the 
heater to service.
e) At no time shall more than one dayʼs supply 
of heater fuel be stored inside a building in 
the vicinity of the heater. Bulk fuel storage 
shall be outside the structure.
f)  All fuel storage shall be located a minimum of 
25 feet from heaters, torches, welding equipment 
and similar sources of ignition (exception: the 
fuel reservoir integral with the heater unit).
g) Whenever  possible,  fuel  storage  shall  be 
confined to areas where floor penetrations 
do not permit fuel to drip onto or be ignited 
by a fire at lower elevation.
h) Fuel  storage  shall  be  in  accordance  with 
the federal, state or local authority having 
jurisdiction.
3.  Never use heater where gasoline, paint thinner 
or other highly flammable vapors are present.
4.  Follow all local ordinances and codes when 
using heater.
5.  Heaters  used  in  the  vicinity  of  tarpaulins, 
canvas or similar enclosure materials shall be 
located a safe distance from such materials. 
The recommended minimum safe distance is 
10 feet. It is further recommended that these 
enclosure materials be of a fire retardant nature. 
These enclosure materials shall be securely 
fastened to prevent them from igniting or from 
upsetting the heater due to wind action.
6.  Use only in well vented areas. Before using 
heater, provide at least a three-square-foot 
opening of fresh, outside air for each 100,000 
Btu/Hr of rating.
7.  Use only in places free of flammable vapors 
or high dust content.
8.  Use only with the electrical voltage and fre-
quency specified on model plate.
9.  Heater must be grounded. Use only a properly 
grounded three-wire extension cord. Plug into 
grounded outlet only.
10.  Minimum heater clearances from combustibles: 
 
Outlet: 8 Ft. 
Sides: 4 Ft. 
 
Top: 4 Ft. 
Rear: 4 Ft.
11.  Locate heater on a stable and level surface 
while hot or running or a fire may occur.
12.  When moving or storing heater, keep heater in 
a level position or fuel spillage may occur.
13.  Keep children and animals away from heater.
14.  Never start heater when combustion chamber 
is hot or if fuel has accumulated in combustion 
chamber.
15.  Unplug heater when not in use.
16.  This heater has a built-in thermostat. Plugged-
in heater may start at anytime.