FUELS
  WARNING:  Use  only  kero-
sene,  #1#2  diesel/fuel  oil,  JET 
A  or  JP-8  fuels  to  avoid  risk 
of fire or explosion. Never use 
gasoline,  naphtha,  paint  thin-
ners,  alcohol  or  other  highly 
flammable fuels.
Do not use heavy fuels such as No. 2 fuel oil or No. 
2 diesel. Using heavy fuels will result in:
•  clogged fuel filter and nozzle
•  carbon build-up on spark plug
•  the need of non-toxic anti-icer in fuel during 
very cold weather
IMPORTANT:
 Use a KEROSENE ONLY storage 
container. Be sure storage container is clean. Foreign 
matter such as rust, dirt or water will cause flame-out 
control to shut down heater. Foreign matter may also 
require you to clean fuel system often.
VENTILATION 
 WARNING: Follow the mini-
mum fresh, outside air ventila-
tion  requirements.  If  proper 
fresh, outside air ventilation is 
not provided, carbon monoxide 
poisoning  can  occur.  Provide 
proper fresh, outside air ventila-
tion before running heater.
Fresh Air Opening Requirements 
 
Heater Size  Square Feet Opening
  350,000 Btu/Hr 
10.5
  600,000 Btu/Hr 
18.0
Note:
 If you use more than one heater, provide extra 
fresh air. Provide a fresh air opening of at least three 
square feet for each 100,000 Btu/Hr rating.
OPERATION 
 WARNING: Review and under-
stand the warnings in the Safety 
Information section, page 2. They 
are needed to safely operate this 
heater. 
TO START HEATER
1.  Follow all ventilation and safety information.
2.  Locate heater to provide maximum circulation 
of the heated air. Follow all location require-
ments noted in Safety Information, page 2.
3.  Fill fuel tank with kerosene, #1#2 diesel/fuel 
oil, JET A or JP-8 fuels.
4.  Attach fuel cap.
5.  Set thermostat dial to desired temperature. 
Note:
 Thermostat setting must be higher than 
surrounding air temperature. 
6.  Plug power cord of heater into three-prong, 
grounded extension cord. Extension cord must 
be at least six feet long.
 WARNING: Use only a three-
prong,  grounded  extension 
cord. Use cord with proper wire 
size to assure 120 volt operation. 
See  Extension  Cord  Wire  Size 
Requirements below.
Extension Cord Wire Size Requirements
6 to 100 feet long, use 14 AWG rated cord
101 to 200 feet long, use 12 AWG rated cord
201 to 300 feet long, use 10 AWG rated cord
301 to 400 feet long, use 8 AWG rated cord
401 to 500 feet long, use 6 AWG rated cord
7.  Plug extension cord into standard 120 volt/60 
hertz, three-hole, grounded outlet. 
8.  The motor will start when extension cord is 
plugged into outlet. The heater should ignite 
at once. If heater does not ignite, restart heater. 
To restart heater, wait 60 seconds, then push 
in flame-out control reset button. Flame-out 
control reset button is at rear of heater near 
power cord (see Figure 4, page 5).
Note:
 A cold heater may affect the thermostat setting. 
This thermostat is a general-heating control. It is not 
intended for precise temperature control. Adjust ther-
mostat until heater cycles at the desired setting.
Note:
 If starting heater for first time, you may need 
to prime the pump. If equipped, slightly open bleed-
er valve of pump to allow air to escape. Quickly 
close valve once fuel is seen. Wipe up any excess 
fuel. If equipped with canister fuel filter, remove the 
canister bottom and fill with fuel. Reassemble filter. 
Wipe up any excess fuel. You may also have to do 
this after taking heater out of storage.