TROUBLESHOOTING
 WARNING: Never service heater while it is plugged in, operating 
or hot. Severe burns and electrical shock can occur. Only a qualified 
service person should service and repair heater. 
OBSERVED PROBLEM
Motor does not start when heater 
is plugged in and thermostat set-
ting  is  higher  than  surrounding 
air temperature
REMEDY
1. A) Check condition of power 
cord or extension cord. Repair 
or replace if damaged
  B)  Use  extension  cord  with 
proper wire size (see To Start 
Heater, page 4)
  C) Make sure heater is plugged 
into 120 volt/60 hertz outlet
2. Check connections. Tighten if 
loose
3. A)  See  Fan  Blades  and Air 
Deflectors, page 10
  B) Remove  debris from  fan 
and fan guard area
  C) Turn fan by hand. If fan is 
hard to turn, see Pump, page 
12
  D) See steps B and C under 
item 1 above
  Note:
 Be sure to reset motor 
overload protector by pressing 
reset button on top of motor
4. Press  and  release  flame-out 
control  reset  button.  See 
Figure  4,  page  4  for  button 
location
5. Replace flame-out control
6. Replace power relay
7. Replace thermostat
8. Turn fan by hand. If fan is hard 
to turn, see Pump, page 12
POSSIBLE CAUSE
1. No power or low voltage at 
heater due to:
  A)  Damaged  power  cord  or 
extension cord
  B) Wrong size extension cord
  C) Heater plugged into outlet 
with voltage lower than 120 
volt 
2. Loose electrical connections
3. Motor  overload  protector 
tripped due to:
  A) Dirty fan
  B) Debris pulled into fan area 
by fan
  C) Binding pump
  D) Low voltage 
4. Flame-out control not reset 
5. Damaged flame-out control 
6. Damaged power relay
7. Damaged thermostat
8. Binding pump