Desa KEROSENE HIGH PRESSURE PORTABLE FORCED AIR HEATERS Manuale Utente

Pagina di 24
www.desatech.com
110098-01F
5
Figure 4 - Flame-Out Control Reset 
Button
Flame-Out 
Control 
Reset Button 
OPERATION 
Continued
TO STOP HEATER
  CAUTION:  Never  unplug 
heater while heater is running. 
Heater must go through purge 
cycle. The purge cycle cools the 
combustion  chamber.  Damage 
to heater can occur if combus-
tion chamber is not cooled. Do 
not  restart  heater  until  purge 
cycle is complete. 
1.  Turn thermostat dial to lowest temperature 
setting. This will cause heater flame to go 
out. The motor will continue to run during the 
purge cycle. This allows the fan to cool the 
combustion chamber. When the purge cycle 
is finished, the motor will stop. Do not unplug 
heater until purge cycle is finished.
2.  Unplug extension cord from outlet.
3.  To temporarily stop heater, set thermostat at 
a temperature lower than air around heater. 
Heater will cycle back on if air temperature 
around heater matches thermostat setting.
TO RESTART HEATER
  CAUTION:  Do  not  restart 
heater  until  purge  cycle  is  fin-
ished. The purge cycle cools the 
combustion chamber. 
1.  Wait until purge cycle is finished after stopping 
heater. 
2.  Repeat steps under To Start Heater, page 4. 
STORING, 
TRANSPORTING OF 
SHIPPING
Note:
 If shipping transport companies require fuel 
tanks to be empty.
1.  Drain all fuel from fuel lines and pump/filter 
(see Fuel Filters, page 12). 
2.  Clean  and  flush  fuel  filter  in  fuel  pump  if 
equipped (see Fuel Filters, page 12).
3.  Remove drain plug and drain fuel tank.
4.  Replace drain plug. 
5.  If any debris is noted in old fuel, add 1 or 2 
quarts of clean kerosene to tank, stir and drain 
again. This will prevent excess debris from 
clogging filters during future use.
6.  Replace fuel cap or drain plug. Properly dis-
pose of old and dirty fuel. Check with local 
automotive service stations that recycle oil.
7.  Add two gallons (350,000 Btu/Hr) or three 
gallons (600,000 Btu/Hr) of clean kerosene, 
#1#2 diesel/fuel oil, JET A or JP-8 fuels to 
fuel tank. 
8.  Replace fuel cap.
9.  Operate heater for 5 minutes (see Operation, 
page 4).
10.  Stop heater and let cool completely.
11.  Remove drain plug and drain fuel tank.
12.  Replace drain plug. 
13.  Properly dispose of old and dirty fuel.
14.  If  storing,  store  heater  in  a  dry  location. 
Make sure storage place is free of dust and 
corrosive fumes.
IMPORTANT:
 Do not store kerosene over summer 
months for use during next heating season. Using 
old fuel could damage heater.