Desa KEROSENE HIGH PRESSURE PORTABLE FORCED AIR HEATERS Manuale Utente

Pagina di 24
www.desatech.com
110098-01F
6
OFF
ENGINE
FUEL
      
F
Figure 5 - Typical Generator Grounding 
Method (Generator construction may 
vary from that shown)
Ground 
Lug 
Ground Wire  
(#10 AWG -  
Stranded-Copper)
Alternator
Copper 
or Brass 
Grounding 
Point 
PREVENTATIVE MAINTENANCE SCHEDULE
 WARNING: Never service heater while it is plugged in, operating 
or hot. Severe burns and electrical shock can occur.
Item
Fuel tank
Filler neck screen
Fuel  filter  assembly  (Fuel 
tank)
Fuel filter lines
 
Fuel filter (In pump or ex-
ternal canister)
 
Spark plug 
Fan blades and air 
deflectors 
Air passages around burner 
head
Motor
How To
See  Storing, 
 
, page 5
Lift out of fuel tank and rinse with 
clean kerosene
See Fuel Filters, page 12
See Fuel Lines, Page 12
See Fuel Filters, page 12
See Spark Plug, page 10
See Fan Blades and Air Deflec-
tors, page 10
Remove debris and trash with a 
clean, soft cloth
How Often
Flush every 150-200 hours of operation 
or as needed
Check for particles in fuel when filling 
fuel tank. Clean when dirty
Clean twice a heating season or replace 
as needed
Check and tighten loose connections 
occasionally
Clean  fuel  filter  element  every  250 
hours
Clean  and  regap  every  300  hours  of 
operation or replace as needed
Clean each season or as needed
Check  each  season  for  dirt  and 
debris
Not required, permanently lubricated
OPERATION WITH 
PORTABLE GENERATOR
 WARNING: Before operating 
heater or any appliance from a 
portable  generator,  verify  that 
generator has been properly con-
nected to earth ground. Improper 
grounding  or  failure  to  ground 
generator can result in electro-
cution if a ground fault occurs. 
Refer to owner’s manual supplied 
by  generator  manufacturer  for 
proper grounding procedures.
The operating voltage range of the heater is 108 to 
132 Volts (120 Volts +/- 10%). Prior to plugging 
heater into generator the output voltage should 
be verified (if generator is equipped with the au-
tomatic idle feature, the output voltage should be 
measured with the generator running at full speed). 
If the voltage does not measure in this range the 
heater should not be plugged into the generator.
Refer to Operation, page 4, for starting, stopping 