Figure 11
Attention: If a base is not used and the appliance is installed directly 
on tile or other combustible material other than wood flooring, it 
shall be installed on a metal or wood panel extending the full width 
and depth of the appliance. The vertical dimension in Figure 11 
must be adjusted when a metal or wood panel is placed beneath 
the appliance.
Finishing (Figures 12 and 13)
Finish the walls with the material of your choice. Figure 3 on 
page 8 shows the minimum vertical and corresponding maximum 
horizontal dimensions of mantels or other combustible projections 
above the top front edge of the fireplace.
The black fireplace front must not be covered. It must be flush 
to the finished wall.
Warning: When finishing the fireplace never obstruct or 
modify the air inlet/outlet louvers in any manner. Provide 
adequate clearances around air openings into the combustion 
chamber.
Caution: If the joints between the finished wall and the fireplace 
surround  (top  and  sides)  are  sealed,  a  300°F  minimum  sealant 
material must be used. These joints are not required to be sealed. 
Only non-combustible material (using 300°F minimum adhesive 
if needed), can be applied as facing to the fireplace.
Figure 10
Framing (Figure 11)
Fireplace framing can be built before or after the fireplace is set in 
place. Framing should be positioned to accommodate wall covering 
and  fireplace  facing  material.  The  fireplace  framing  should  be 
constructed of 2 x 4 lumber or heavier. The framing headers may 
rest on the fireplace standoffs. Refer to Figure 11 for minimum 
framing dimensions.
CAUTION:  MEASURE  FIREPLACE  DIMENSIONS AND 
VERIFY FRAMING METHODS, AND WALL COVERING 
DETAILS  BEFORE  FRAMING  CONSTRUCTION 
BEGINS.
Framing  dimension  "A"  includes  a  six  inch  clearance 
for  standoffs  on  fireplace.  After  installing  fireplace  into 
framing, the finished non-combustible wall surface must 
cover the six inch opening above the fireplace.
Attention: Appliance  must  not  be  recessed  below  any  flooring, 
including carpeting, for proper front mounting. A metal or wood 
panel  extending  the  full  width  and  depth  of  the  appliance  may 
be required to raise the unit to the same level, or above existing 
flooring. The vertical dimension in Figure 11 must be adjusted 
when a panel is placed beneath the appliance.
NAIL OR OTHER
SUITABLE FASTENER
INSTALLATION (continued)
DVX36 DVX42
"A"
40 7/8"
40 7/8"
"B"
40 3/8"
43 3/8"
"C"
19 7/8"
19 7/8"