Flush Wall Installation
Figure 12
Combustible Surround Installation
Figure 13
Vent Runs (Figures 14, 15, and 16)
In planning the installation for the fireplace, it is necessary to install 
certain components before the appliance is completely positioned 
and installed. These include the direct vent system, gas piping for 
the appliance and the electrical wiring.
The appliance can be mounted on any of the following surfaces:
1. A flat, hard combustible (burnable) surface.
2. A raised wooden platform.
3. Four (4) corner supports. (Example: Four (4) concrete masonry 
blocks.) These supports must be positioned so they contact all 
four (4) perimeter edges on the bottom of the unit.
VERTICAL, 90° ELBOW WITH HORIZONTAL 
TERMINATION
Figure 14
FINISHED WALL
JOINT BETWEEN FINISHED
WALL AND UNIT SEALED
WITH 300° F, 149° C SEALANT
MATERIAL (SEALANT IS OPTIONAL)
6” OF NON-COMBUSTIBLE MATERIAL
NON-COMBUSTIBLE MATERIAL
(INSTALLATION IS OPTIONAL
FINISHED WALL
COMBUSTIBLE SURROUND
MANTELSHELF
2 X 4
HEADER
STAND OFF
6” OF NON-COMBUSTIBLE
MATERIAL
FRONT TRIM OR
NON-COMBUSTIBLE
MATERIAL (INSTALLATION
IS OPTIONAL)
JOINT BETWEEN FINISHED
WALL AND UNIT SEALED WITH
300°F (149°C) SEALANT MATERIAL
(SEALANT IS OPTIONAL)
Attention:  Cold  climate  installation  recommendation: 
When installing this unit against a non-insulated exterior 
wall, it is recommended that the outer walls be insulated to 
conform to applicable insulation codes.
3” (76mm)
MINIMUM CLEARANCE
TO COMBUSTIBLES
VENT CAP/
THIMBLE
WALL FIRESTOP
DVX36,42
50 1/2” (1283mm)
TO BOTTOM
OF UNIT