Desa CGCDV42NR Manuale Utente

Pagina di 44
www.desatech.com
116236-01E
28
7.  Turn gas control knob counterclockwise 
 to “PILOT”. (see Figure 44)
8.  Push in gas control knob all the way and 
hold. Immediately light the pilot by repeat-
edly depressing the piezo spark ignitor until 
a flame appears. Continue to hold for about 
one (1) minute after the pilot is lit. Release 
gas control knob and it will pop back. Pilot 
should remain lit. If it goes out, repeat steps 
5 through 8.
•  If gas control knob does not pop up when 
released, stop and immediately call your 
service technician or gas supplier.
•  If the pilot will not stay lit after sev-
eral tries, turn the gas control knob to 
“OFF” and call your service technician 
or gas supplier.
9.  Turn on all electric power to the fireplace.
10.  Turn gas control knob counterclockwise 
 to “ON”.
11.  This valve is equipped with a HI/LO fea-
ture. Set fireplace input as desired.
12.  Close lower louver panel.
OPERATING FIREPLACE
Continued
O
F
  PILOT   
LO 
IH 
O
N
     
    
    
   
Figure 44 - Control Valve
Piezo Ignitor
Gas Control 
Knob
Variable Control Knob
TO TURN OFF GAS 
TO APPLIANCE
1.  Open lower louver panel.
2.  Set selector switch in the OFF position to 
prevent draining battery.
3.  Turn off all electrical power to the appliance 
if service is to be performed.
4.  Push in gas control knob slightly and turn 
clockwise 
 to “OFF”.
5.  Close lower louver panel.
Shutting Off Burners Only (pilot stays lit)
You may shut off the burners and keep the pilot 
lit by doing one of the following:
1.  Turn gas control knob clockwise 
 to the 
PILOT position.
2.  Set selector switch in the OFF position.
MANUAL LIGHTING 
PROCEDURE
1.  Remove glass door (see Removing/Replacing 
Glass Door, page 25).
2.  Follow steps 1 through 8 under Lighting In-
structions, page 27.
3.  Depress gas control knob and light pilot 
with match.
4.  Keep gas control knob pressed in for 30 sec-
onds after lighting pilot. After 30 seconds, 
release gas control knob. Follow steps 9 
through 12 under Lighting Instructions.
5.  Replace glass door (see Removing/Replacing 
Glass Door, page 25).
OPTIONAL HAND-HELD 
REMOTE OPERATION
Note:
 All remote control accessories must be 
purchased separately (see Accessories, page 
42).  Follow  instructions  included  with  the 
remote control. 
NOTICE: You must light the pilot 
before using the hand-held re-
mote control unit. See Lighting 
Instructions, page 27.
After lighting, let pilot flame burn for about 
one minute. Turn control knob to ON position. 
Adjust flame adjustment knob anywhere be-
tween HI and LO. Slide the selector switch to 
the REMOTE position (see Figure 45). Note
The burner may light if hand-held remote was 
on when selector switch was last turned off. 
You can now turn the burner on and off with 
the hand-held remote control unit. 
IMPORTANT:
 
Do not leave the selector switch 
in the REMOTE or ON position when the pilot 
is not lit. This will drain the battery.
OF
F   
PIL
O
T
   
LO
 
IH
 
ON
OFF
REMOTE
ON
OFF
O
N  
          
    
Blower Control Knob
(Optional Accessory)
Variable 
Control 
Knob
Selector Switch in 
Remote Position
Gas Control Knob 
in ON Position 
Figure 45 - Setting the Selector Switch, 
Gas Control Knob and Variable Control 
Knob for Remote Operation