Clavia c1 Guida Utente

Pagina di 20
Nord C1 Combo Organ
System Functions
 OS V1.0X
15
System Functions
ABOUT SYSTEM SETTINGS
System settings are global; they are not stored within a 
program, but applies to all programs all of the time.
The system settings are divided into 3 menus:
• System menu
• MIDI  menu
• Sound menu
A list of each menu and it’s functions is printed on the front 
panel.
CHANGING SYSTEM SETTINGS
To change a a system function:
1
Select the appropriate menu
Press 
SHIFT
 + 
SYSTEM
 / 
MIDI
 / 
SOUND
 buttons.
2
Select function
The current functions number is shown in the 
DIS-
PLAY, as well as it’s current setting. Navigate through 
the available functions by using the 
PROG/MENU
 but-
tons. 
3
Change setting
Press 
SHIFT
 + 
VALUE
 buttons to navigate though the 
functions possible settings.
Changes are automatically saved.
4
Press any of the 
SYSTEM / MIDI / SOUND 
buttons to 
exit the menu
THE SYSTEM MENU
THE MIDI MENU
1 Memory protect
default value: 
OF
ON
Program store is disabled.
OF
Program store is enabled.
2 Output Routing
default value: 
ST
SP
Split Output: tonewheel organ is directed to 
HIGH LEVEL 
OUT and LEFT OUT. 
Electric-V and Electric-F organs are directed to 
RIGHT 
OUT.
ST
Stereo Output. 
3   Transpose
default value: 
0
-6 - +6
Sets transpose of both manuals and 
BASS PEDAL input in 
range of -6 semi notes to + 6 semi notes, steps of 1 semi 
note.
4   Fine  Tune
default value: 
40
27 - 53
Sets the tuning from 427 Hz to 453Hz, in steps of 1 Hz. 
Default value is 40 (440Hz).
5  Sustain Pedal Polarity
default value: 
CL
CL
Pedal Closed: for use with a sustain pedal with closed polar-
ity.
OP
Pedal Open: for use with a sustain pedal with open polarity.
6   Sustain  Pedal
default value: 
ON
Controls weather the selected organ model should respond to sustain 
pedal messages. When a pedal is connected to the 
SUSTAIN PEDAL 
input, sustain pedal messages are always send via 
MIDI OUT regard-
less of this setting.
ON
Sustain pedal messages enabled.
OFF
Sustain pedal messages disabled.
7   Rotary  Control  Type
default value: 
CL
Specifies the type of controller connected to the Rotary Control input. 
If the Half Moon Switch option is selected the speed control buttons 
on the front panel are disabled. 
HA
Half Moon Switch: for use with the Half Moon Switch acces-
sory.
OP
Pedal Open: For use with a sustain pedal with open polarity.
CL
Pedal Closed: For use with a sustain pedal with closed 
polarity.
8   Rotary  Pedal  Mode
default value: 
HD
TO
Toggle: rotary speed is changed between 
SLOW and FAST 
each time the pedal is pressed down. By holding the pedal 
pressed downed for the duration of 1 second the speed will 
change to 
STOP. 
HD
Hold: rotary speed follows the state of the pedal.
9  Swell Pedal Type
default value: 
RO
Here you can match the swell pedal characteristic for various manu-
facturers.
FA
Fatar.
ER
Ernie Ball.
YA
Yamaha.
RO
Roland.
10  Factory Reset
 
Press 
STORE to recall all system settings. Stored PROGRAM MODE 
data is not affected. 
LIVE 1 and LIVE 2 data will be overwritten.
1 Upper Channel
default value: 
1
Sets how messages are sent and received from the 
UPPER manual via 
MIDI IN and MIDI OUT.
OFF
 Messages are not sent.