Cooling Sub-System 
 
Revision 1.5 
Intel order number: E80367-002 
31
 
Figure 12. Cooling Fan Configuration for Intel
®
 Server Board S5500BC  
The Intel
®
 Server System SC5650BCDP is engineered to provide sufficient cooling for all 
internal components of the server. The cooling subsystem is dependent upon proper airflow. 
The designated cooling vents on both the front and back of the chassis must be left open and 
must not be blocked by improperly installed devices. All internal cables must be routed in a 
manner that does not impede airflow, and ducting provided for CPU cooling must be installed. 
Active heatsinks for CPUs incorporate a fan to provide cooling. The Intel
®
 Server System 
SC5650BCDP is engineered to work with processors that have an active heatsink solution. 
Heatsink thermal solutions are sold separately, be sure that you use one that is rated for the 
wattage of your processor. Proper installation of the processor cooling solution is required for 
circulating air toward the rear of the chassis (toward I/O connectors). 
4.3.1 
System Fan Connectors 
The Intel
®
 Server System SC5650BCDP supports three system fans. The Intel
®
 Server Board 
S5500BC supports five SSI compliant 4-pin fan connectors. The two 4-pin fan connectors are 
for processor cooling fans: CPU_1 fan (J3K1) and CPU_2 fan (J7K2). The three 4-pin fan 
connectors are for system fans system fan 1(J3K2), system fan 2(J8K3), and system fan 3 
(J8B4).  
Fan 
Connect to fan connector 
Rear Chassis Fan  
System Fan 3 
HDD Bay Fan 
System Fan 2 
PCI Zone fan 
System Fan 1