Scanning the Targets with the Document Feeder (DADF)
1. Place all of the target sheets in the Document Feeder. The orientation of a target
sheet is not important when using the DADF.
2. Select the Scan Chart with Document Feeder button on the UI.
3. Select Scan.
4. After the scanning completes, select Start.
5. To continue, go to
Scanning the Targets with the Platen Glass
1. Select the Scan Chart with Document Glass button on the UI.
In the next steps, you will scan the Calibration Chart 4 times; 2 times per side. For
each scan you will reposition the chart.
For each scan do not place the target against the registration edge, but leave at least
20 mm to the edge of the glass. Also makesure the target is not skewed more than
15 degrees:
2. Open the cover of the Automatic Document Feeder (ADF). Notice that the Control
Panel now displays the Auto Alignment Adjustment screen. The instructions on this
screen will assist you in performing the next several steps. Notice that the bottom
right of the screen displays: Scan Page(s): 0.
The next series of steps will be performed 4 times; twice for each side of the Alignment
Adjustment Calibration Chart that you printed.
3. To position the Calibration Chart and the Background Plate onto the glass, perform
the following:
a) Place the Background Plate on the document glass and align it to the rear left
corner, as shown on the UI.
The all-black side of the document should be placed face down on the document
glass. The side of the document with the instructional icons should face up. Note
that these icons are identical to those displayed on the UI.
b) Select one of the five Calibration Charts that you printed.
Xerox
®
Versant
®
80 Press
4-4
System Administration Guide
Simple Image Quality Adjustment (SIQA)