Cisco Cisco Unified MeetingPlace 5.3 Manuale Di Manutenzione

Pagina di 4
 
4
Power Supply Replacement Procedure for the Cisco MeetingPlace 8112
OL-6464-01
  How To Replace the Power Supply
Installing a New Power Supply
Warning
Do not touch any of the exposed leads, terminals, or components. Hazardous voltages, capable of 
causing death, may be present in this product.
Step 1
Remove the new power supply from the antistatic bag.
Step 2
Insert the bottom edges of the power supply into the rail guides in the power supply bay. If you can tilt 
the power supply more than 2 degrees after it is in the power supply bay, both edges are not in the rail 
guides.
Step 3
Slide the power supply into the power supply bay until it stops.
Note
Insert the power supply with a single, steady motion. Bouncing the power supply during 
insertion may cause an alarm condition in the Cisco MeetingPlace system.
Step 4
Use a Phillips screwdriver to replace the two captive screws that secure the power supply to the 
Cisco MeetingPlace 8112 chassis. These screws are located at the bottom of the power supply.
Verifying that the New Power Supply Works Correctly
Step 1
Check the LEDs. See the 
. If the LEDs do not look normal , try reseating the power supply. See 
.
Step 2
Enter hwconfig. See the 
. If the hwconfig output does not look normal , try reseating the power supply. See 
.
Step 3
If you reseat the power supply and still have problems, examine the power supply connectors to see if 
they are damaged or dirty. If both sides of the connectors look good, try installing another power supply.
If the second power supply installs and works correctly, send the power supply you tried to use as a 
replacement first back to the factory. If the second power supply does not install or work correctly, 
contact Cisco TAC.