Cisco Cisco Packet Data Gateway (PDG) Guida Alla Risoluzione Dei Problemi

Pagina di 5302
Global Configuration Mode Commands   
▀  threshold poll dcca-bad-answers 
 
▄  Cisco ASR 5000 Series Command Line Interface Reference 
OL-22948-01   
threshold poll dcca-bad-answers 
This command configures the polling interval for DCCA Bad Answers threshold—invalid or bad response to the system 
from the Diameter server. 
Product
 
ECS 
Privilege
 
Security Administrator, Administrator 
Syntax
 
Configures the default setting. 
Default: 900 seconds 
Specifies the poling interval for DCCA Bad Answers threshold, in seconds. 
 must be an integer value from 60 through 60000. 
Usage
 
This command configures the poling interval for DCCA Bad Answers threshold. 
Important:
  All configured polling intervals are rounded up to the closest multiple of 30. For example, if a polling 
interval is configured for 130 seconds, the system uses a polling interval of 150 seconds. 
Refer to the 
 and other threshold commands for additional information on the 
system‘s support for thresholding in this chapter. 
Example 
The following command configures the polling interval to 600 seconds for invalid or bad response threshold to the 
system from Diameter server: