Configuring Transport Stream Information 
 
OL-29015-01 
197 
 
13  In the Instance field, enter the instance (1 to 64) of the service specified by 
Category to configure. If an input service matches this type and instance, then 
the Action will be applied.  
14  If Action is set to Map, enter the Output PID number (0 to 8192) in the Output 
PID field. 
15  Click Save
16  Click OK
To remove a PID mapping, click the radio button of the entry you want to 
remove and click Delete
 
Synchronizing the Inputs 
1  
In the DPM Program Entry Setup table, each PE output can be synchronized to 
its input according to one of the four output modes. Select the program entry 
you want to synchronize and then click Resynchronize or click Resynchronize 
All
 to synchronize the inputs to the outputs according to the service assignments 
only. The Confirm Resynchronization window is displayed. 
 
2  Select whether you want to synchronize the PE output according to the services 
and then the PIDs assigned to each service, services only, PIDs only, or to 
synchronize using a template. 
Map Mode 
Description 
Resynchronize Program, PMT 
PID, ES List & ES PIDs 
The receiver will synchronize the PE output according to 
the services and then the PIDs assigned to each service. 
Resynchronize ES List 
The receiver will synchronize the PE output according to 
the available input services only, and ignore the input to 
output service PID mapping. 
Resynchronize ES PIDs 
The receiver will synchronize the PE output according to 
the input PIDs only, and ignore the service assignment 
categories/names. 
Resynchronize Template ES List 
& PIDs 
Allows you to preset the input to output mapping of a PE 
according to the preset template. This is helpful in pre-
configuring any number of PEs for future use. 
3  Click OK