Cisco Cisco Content Delivery Engine 250 Guida All'Installazione

Pagina di 14
 
 
2.3.1 Validation using the IPMI port 
Login to IPMI web GUI and the login page / System Information Page shows the IPMI firmware 
Revision. 
The Firmware Revision should be “3.06” as shown in the image below: 
 
 
 
2.3.2 Validation on CDS-TV 
Verify the IPMI FW using the following command: 
CDE250_Streamer# cat /sys/devices/platform/ipmi_bmc.aabb.32/firmware_revision 
This should return “3.6” 
Note: Linux will usually strip the “0” from the 3.06 string. 
Execute the “sdt” CLI command.  Verify this command does not hang (example output is 
shown below): 
CDE250_Streamer# sdt 
 
***************************************************************************** 
 SuperDoctor II - Linux version 2.111(140922) 
 Copyright(c) 1993-2014 by Super Micro Computer, Inc. http://supermicro.com/ 
***************************************************************************** 
Monitored Item            High Limit  Low Limit     Status 
---------------------------------------------------------------------- 
Fan1 Fan Speed                              715       7031 
Fan7 Fan Speed                              715       5625 
Power1 Fan 1 Speed                         4007       7786 
Power1 Fan 2 Speed                         4007      12251 
Power2 Fan 1 Speed                         4007       8129 
Power2 Fan 2 Speed                         4007      12137 
CPU1 Vcore Voltage              1.49       0.60       1.06 
CPU2 Vcore Voltage              1.49       0.60       1.20