Cisco Cisco Content Delivery Engine 250 Guida All'Installazione

Pagina di 14
 
 
2.3.5 Validation on VQE 
Verify the IPMI FW using the following command at the console: 
root@]# ipmiutil sel show 
 
This command should return the following value for the “BMC version” 
 
ipmiutil ver 2.51 
showsel: version 2.51 
-- BMC version 3.6, IPMI version  
SEL Ver 51 Support 3, Used = 1 records, Free space = 574 records 
RecId Date/Time_______ Source_ Evt_Type SensNum Evt_detail - Trig [Evt_data] 
0001 02/19/15 02:58:43 BMC  08 Power Supply #1a is OK   ef [01 ff ff] 
showsel completed successfully 
Note: Linux will usually strip the “0” from the 3.06 string. 
 
 
 
 
 
3  Superdoctor 2.111  
3.1 Download Superdoctor 2.111 
 
Download Superdoctor 2.111 from the following URL: 
 
 
 
 
1)  Select “SD2_2.111.456-140922.tar.gz” to download  
2)  Copy the /SD2_2.111.456-140922.tar to /tmp 
 
3.2 Install Superdoctor 2.111 
 
1)  cd to /usr/sbin 
2)  tar -xvf /tmp/SD2_2.111.456-140922.tar/SD2_2.111.456-140922.tar 
i.  This will extract to /usr/sbin/superdoctor 
3)  Rename the “/usr/sbin/superdoctor/sdt.x86_64 file” to “sdtsdt”  
a.  cp /usr/sbin/superdoctor/sdt.x86_64 sdt 
4)  Rename the “/usr/sbin/sdt” to “sdt.org”  
a.  cp /usr/sbin/sdt sdt.org