290B Outdoor housing
4. Attach the camera to the camera mounting board (7) using the screw attached to the 
board. You will find a screw hole at the bottom of the camera. Before tightening the 
screw, position the camera with the board inside the housing (with the lens to the 
front) and determine the camera’s correct position.
Caution:
 The lens should be as close to the window as possible allowing sufficient space between the lens 
and window to accommodate the zoom function (if supported). 
5. Once the correct position has been established, lift out the camera with the board 
while keeping it in the correct position. Tighten the screw at the bottom to securely 
affix the camera to the board.
Caution:
 The heater at the front of the housing unit becomes hot when in operation. If applicable, position 
the cable connected from the DC IRIS socket to the lens so that it does not touch the heater.
Caution:
 Do not over-tighten the screw as you may damage the camera.
6. Position the camera with the board inside the housing as before. Make sure the board 
is inserted under the lugs beneath the window in its most forward position. Use the 
two screws (6) to secure the board with the camera and lens in the housing.
7. Close the housing with the two clips on the side.
Routing the cables
1. Route the cables (network and power) to the location where the bracket arm is to be 
installed. 
Note: 
The cables can either be routed through the bracket arm (recommended) or through a hole in the base of 
the bracket. This hole needs to be drilled in the recess area where the casing metal is thinner to accommo-
date easy drilling. 
Determine the size of the hole to accommodate the fitment of the cable gland (not supplied). However, the 
hole should not exceed 15mm in diameter. 
Warning:
 Install cable glands and/or cables that are suitable for external use that and are in compliance 
with local laws and regulations.