Axis 25205 Manuale Utente

Pagina di 8
290B Outdoor housing
Installing the housing
Recommendation:
 Keep the housing closed when possible to prevent the build-up of dust and 
moisture inside the housing.
Important:
 This product should be installed by certified electrical technicians in compliance 
with local laws and regulations.
Warning:
 High voltage. Ensure that the power is disconnected before starting any work or 
opening the housing.
If you do not wish to use the included power cable, refer to the following dimension 
guidelines:
Maximum power cable length
Minimum cable conductor area
330 ft. (100m) 
260 ft. (80m) 
160 ft. (50m) 
100 ft. (30m) 
AWG 13 - 0.0040 sq. inch (2.6 mm
2
AWG 14 - 0.0031 sq. inch (2.0 mm
2
AWG 16 - 0.0020 sq. inch (1.3 mm
2
AWG 18 - 0.0012 sq. inch (0.78 mm
2
* AWG = American Wire Gauge
Important!
No.
8.   Housing
9. White rubber seal
10. Widget
11. Swivel
12. Bracket arm
13. Positioning bolt
9
 8
1
12
10
11
13
.
• The white molex connector on the supplied power cable should be connected to 
the power supply only and cannot not be routed to the camera housing.
• The cable’s conductor area is proportionate to its length. Using smaller cable 
area measurements may seriously damage the unit.
• The maximum power cable length is 330 feet (100 meters).