HP designjet l65500 Manuale Di Servizio

Pagina di 12
Preventative Maintenance
 Preventive Maintenance
781
The reason for this is when doing a cycle of the PPS (raising up and lowering back), the counter does not 
increase by 1, but by 4 on average, so the threshold will be increased to 8000 instead of 2000.
Note 5: Corresponding counter in component usage of the service plot: Tube ISS # cycles.
Printer with serial number ok (SG94S1F001), on one which the preventive maintenance #5 has not been 
performed (tube not replaced), will have a preventive maintenance #5 displayed with the number of 
cycles of the scan axis reaches 900 000 (from FW version 14.2.2.1).
Once the preventive maintenance #5 has been applied, and the reset from the service menu has been 
done (PMKIt#5), this preventive maintenance #5 is disabled (even if it is all the time displayed). It remains 
the preventive maintenance #2 (carriage chain assy replacement).
It is very important to reset the maintenance kit usage each time you perform preventive maintenance 
action See page 420.
Operator maintenance alerts
The HP Internal Print Server displays alerts whenever a maintenance action is required. The following 
seven alerts require action from the customer, and must be performed according to the life counter value 
on the right (which is calculated into a percentage automatically).
For more information about these procedures, refer to the Maintenance and Troubleshooting Guide.
Note 1: The corresponding counter in not visible in the service plot, but can be calculated from the 
preventive maintenance chapter, by applying, at the line 'heating sensor', the column 'capacity'*'current 
usage'.
Note 2: The corresponding counter is available in the service plot, in the component usage section, Line 
sensor since last clean (milliliters) with a corresponding threshold: 80 000 000 (80l), number reported 
with 000 more than ml.
Note 3: The corresponding counter is available in the service plot, in the component usage section: Usage 
oil reservoir (m), with a corresponding limit of 500 000 m (500km of the carriage movement distance).
Note 4: The corresponding counter is available in the service plot, in the component usage section: Usage 
slider rods (m), with a corresponding limit of 3 000 000 m (3000km of the carriage movement distance).
Note 5: The corresponding counter is available in the service plot, in the component usage section, 
Carriage lid usage (milliliters), with a corresponding threshold: 80 000 000 (80l), number reported with 
000 more than ml.
Note 6: The corresponding counter is available in the service plot, in the component usage section, Ink 
deposit level (cc) , with a corresponding threshold: 136 000 (136l).
Alert
Life Counter Value 
(Values are Approximate)
Clean the Temperature Sensor
80 liters (see note 1)
Clean the Line Sensor
80 liters (see note 2)
Replace the Sensor Box
No limit
Replace the oil reservoirs
6250 square meters (see note 3)
Clean the carriage rails
37501 square meters (see note 4)
Clean the carriage cover
80 liters (see note 5)
Clean the ink deposits
136 liters (see note 6)