Adam Equipment cbw 6 Manuale Utente

Pagina di 28
 
7.4  ACCUMULATION OF DATA IN MEMORY WHEN [PRINT] IS 
PRESSED   
 
•  To accumulate weight in the memory when [Print] is pressed, set 
the scale to "ACC on".  
 
•  To use the [Print] key to only print the weight without adding it to 
memory, set to "ACC oFF".  
 
• Press [Tare] to change the setting between on and oFF. 
 
• Press the [Zero/Enter] key to store the changed setting and 
move to the next parameter. 
 
7.5  AUTO ZERO RANGE   
 
•  The auto-zero will automatically set the scale to zero when the 
displayed weight is almost near zero. This helps to make sure that 
the scale is measuring weight from an accurate zero starting 
point. 
  
•  The Auto zero value can be set to 0.5, 1, 2 or 4 scale divisions. 
The normal setting is 1 scale division. It will show “A2  1d”.  
 
• Press the [Tare/Ï] key to change the value. 
 
• Press the [Zero/Enter] key to store the changed setting and 
move to the next parameter. 
 
7.6  SELECTABLE UNIT OF WEIGHT DISPLAYED 
 
•  The scales are normally set to display in kilograms, however they 
will show the weight in grams, if enabled.  
 
•  The display will show “Ut  on” or “Ut  oFF”. 
 
• Press [Tare/Ï] to change the setting between on or oFF. 
 
• Press the [Zero/Enter] key to store the changed setting and 
move to the next parameter. 
 
© Adam Equipment Company 2007 
16