blue-seal e1100 Manuale Utente

Pagina di 41
-19- 
Revision 4/F3591 
© Moffat Ltd, August 2004 
6.1  FAULT DIAGNOSIS 
Incorrect electrical supply 
Check  that  the  voltage  across  phase  and  
neutral (L1 and L2) terminals of terminal block 
is the voltage as stated on the unit’s electrical 
rating plate. 
If  incorrect,  check  electrical  connection  of  
supply wiring and / or check electrical supply. 
 
Power switch faulty 
With switch on, check voltage at terminal 1 of 
switch.  If there is no voltage, check for fault in 
wiring.  Check voltage at terminal 2.  If there is 
no voltage then the switch is faulty - replace. 
6.1.1  OVEN DOES NOT OPERATE / START 
6.1.2  FAN DOESN’T OPERATE 
Fan switch faulty 
Check  that  the  thermostat  has  power  to  
terminal 5 on switch body on the front of the 
thermostat when power switch is ON.  If no 
voltage check wiring.  Check that terminal P5 
has power switched to it when the thermostat 
is turned on.  If no power to P5 then switch is 
faulty and thermostat complete with switch 
needs to be replaced. 
 
Microswitch faulty / out of adjustment 
Remove the right hand side panel to allow  
access  to  the  microswitch.   With  the  
thermostat  switched  on  and  door  closed, 
check voltage to terminal com of microswitch.  
If no voltage check wiring to thermostat. 
If  voltage  correct  then  check  voltage  at  
terminal  n.c.  If no  voltage  then  manually  
activate microswitch by bending the activator 
arm.  If microswitch cannot be activated then 
it is faulty - replace.   If the microswitch can be 
manually activated then it should be adjusted. 
6.1.3  NO HEAT / ELEMENTS NOT  
WORKING (FAN OPERATES BUT NO 
HEATING INDICATOR) 
No power to thermostat 
With the thermostat ON and the roast switch 
OFF, check for power at terminal 1 of the  
thermostat.   If  no  power  then  check  that 
power is being supplied to the roast switch 
(terminal 2). 
 
Thermostat faulty 
With thermostat turned on (in a cold oven) 
check  for  voltage  at  terminal  2  of  the  
thermostat.  If no voltage at terminal 2, but 
voltage at terminal 1 (with thermostat turned 
on) then the thermostat if faulty - replace. 
Figure 6.1.1 
Microswitch 
com 
n.c. 
Fan motor faulty 
Check the supply voltage across motor termi-
nals.  If there is no voltage then check the 
electrical connections of wiring. 
If voltage is correct then check the oven fan 
for free rotation.  Remove any obstruction. 
If fan is free to spin and the voltage at motor 
terminals is correct, then the motor is faulty—
replace. 
6.1.4  NO HEAT / ELEMENTS NOT  
WORKING (HEATING INDICATOR 
ON) 
Faulty contactor 
With the thermostat on check that the coil of 
the heating contactor is energised (voltage 
between terminals A1 and A2).  Check for  
output voltage from the contactor (terminals 1, 
3 and 5).  If no output voltage (and input to 
terminals  2, 4  and  6  is  correct)  then  the  
contactor is faulty - replace.