Konica Minolta 7013 psc Manuale Utente

Pagina di 166
TCP/IP Configuration-43
2. Type 1 again and press [Enter]. The IP Address submenu will appear:
3. Enter a new IP Address and press Enter. Repeat the previous steps to change 
Subnet Mask and Default Gateways.
4. Enter 4 to change the base port number. 
Note:
The base port number is one less than the actual TCP/IP port number used by the 
printer. For example, to set the port number to 9100, enter 9099.
7.6.3 Select Printer Languages
Selection 2 in the Main Menu allows you to designate which emulations (printer inter-
preter languages) the printer supports. This is to allow the resident lpd/lpr to modify 
files intended for other emulations so that they may be printed. The menu also allows 
you to enable or disable banners attached to lpd/lpr handled jobs.
The emulation choices are Printer Control Language (PCL), PostScript (PS), ASCII 
(simple text) and Other (any print job not recognized as PCL, PS, or ASCII). The file 
modifications and conditions are:
The Configuration Utility
Unit Serial no. 221963
1. IP Address              199.92.187.37
2. Subnet Mask           255.255.255.0
3. Default Gateway     199.92.187.254
4. Base Port Number   10000         
Print Server Setup
Job Detected to be 
Action
PCL, (PostScript)
ASCII
<CR> changed to <CR><LF>
PostScript
PCL, Other
PostScript header added
not PostScript
PostScript
Job discarded
PostScript
ASCII
PostScript  header added, <CR> 
changed to <CR><LF>
PCL, PS, ASCII
any
no action