ZTE Corporation RSUC1930 Manuale Utente

Pagina di 53
ZXSDR RSUC User Manual
Caution:
Protect an optical fiber with the winding tube when routing the
optical fiber inside the cabinet. Protect an optical fiber with
the corrugated pipe when routing the optical fiber outside the
cabinet.
E
ND OF STEPS
Installing the Interconnected
Cable Between BBU and
RSU
Prerequisites
The ZXSDR RSUC cabinet has already been installed.
The BBU module and RSU module have already been installed.
Context
ZXSDR RSUCIn the system, optical fibers or SFP cables can be
used to connect BBU and RSU. During the stacked installation of
the ZXSDR RSUC, a 2 m SFP high-speed cable is recommended
for interconnecting BBU and RSU.
shows an SFP cable.
F
IGURE
16 H
IGH
-S
PEED
C
ABLE
Steps
1. Affix temporary labels to both ends of the SFR cable, with
markings 0-5 to set up one-to-one mapping with interfaces
TX0RX0 to TX5RX5 of BBU and six TX/RX interfaces of RSU.
2. Insert one end of the SFP cable to a TX/RX interface of RSU.
38
Confidential and Proprietary Information of ZTE CORPORATION