Chapter 4 - System Functions 
Confidential and Proprietary Information of ZTE CORPORATION 59 
The OB06 power control is optional, which is indicated by the 
parameters in the BS POWER CONTROL or CHAN ACTIV message. By 
changing the transmission power, the TRX tries to control the power 
control parameter within a certain range according to the message 
requirement (the CHP module implements this operation). 
The maximum power of the TRX is determined by the network design 
specifications, but the BSC can specify a smaller maximum power 
value in the BS POWER CONTROL and CHAN ACTIV messages. 
3. Physical environment request/acknowledgement 
The procedure of physical environment request/acknowledgement is 
shown in Figure 46. 
F
I G U R E  
4 6
 
P
H Y S I C A L  
E
N V I R O N M E N T  
R
E Q U E S T
/ A
C K N O W L E D G E M E N T
 
MS
LAPDm
FURRM
HPIMan
LAPD
BSC
OAMM
DL _ DATA _IND (PHYS 
CONTEXT REQ )
(PHYS 
CON- TEXT 
REQ)
DL_DATA _REQ (PHYS 
CONTEXT CONF)
(PHYS 
CON- TEXT 
CONF) 
 
This optional procedure enables the BSC to obtain the physical 
environment information before the channel change. 
The physical environment information can be sent to a new TRX (which 
may be in another cell). 
The PHY CONTEXT CONF message to be returned by the OB06 to the 
BSC contains the MS/BS power and TA that are obtained from the 
channel, and the OB06 does not process the physical environment 
information temporarily. 
4.  SACCH fill-in information change 
The procedure of modifying the SACCH fill-in information is shown in 
Figure 47. 
F
I G U R E  
4 7
 
S A C C H   F
I L L
-
I N  
I
N F O R M A T I O N  
C
H A N G E
 
MS
LAPDm
FURRM
HPIMan
LAPD
BSC
OAMM
DL_ DATA_ IND (SACCH 
INFO M ODIFY)
(SACCH INFO 
M ODIFY)
M PH_RRCm dToCHP 
(CHP SET/ STOP 
SACCH INFO )
(SYS INFO TYPE 
5/6 /5bis / 5ter)
 
The BSC instructs the OB06 that the new system message ((RR) 
System Information Type 5/5bis/5ter/6) will change the original 
system message that is filled in the SACCH.