Tagsys S.A. LIBSECPEDEST2 Manuale Utente

Pagina di 50
LIBRARY SECURITY PEDESTAL 2 
 
7. Insert the power supply cable into the Electronics Unit through the cable access hole as shown 
above. Check that the cable is correctly positioned and that there are no friction points. 
 
8.  Insert and fasten the screws in the mounting holes according to the type of ground surface: 
a.  Wood floor: Insert the screws directly into the mounting holes and tighten the screws in 
place.  
b.  Concrete floor: Insert the screws into the concrete floor plugs and tighten the screws in 
place. 
 
CAUTION:
 When tightening the screws in place, first tighten the screws in place ¾ of the way. 
Once all screws are in place, then tighten each screw progressively, one after each other to 
ensure that the floor bracket is solidly fixed into place and completely vertically aligned. The 
use of a level may be required. 
 
9.  Unplug the connector block. Strip the 3 wires from the power supply cable and connect them to 
the connector block provided according to the instructions below as indicated on the PCB. 
Please see figure below. 
Figure 5: Connector Block 
 
System Fuse
Line 
 
Neutral 
Earth 
Connector Block 
 
 
CAUTION
: Fix the main power cable using the specific clip as shown in 
Figure 6: Power Cable Fixing 
18/50 
Revision 1.0 
December 2004