Note that the “Static Configuration” interface is the only interface that has a fixed address that 
cannot be changed by the user. Since this interface is known to always be present, it can be 
used  for  initial  configuration  and  for  accessing  devices  whose  configuration  settings  are 
unknown. 
2.2 
Connecting to an Unconfigured EnRoute500 
Use  the  Static  Configuration  interface  with  IP  address 
169.254.253.253  and  netmask 
255.255.0.0 to establish network connectivity to an unconfigured EnRoute500. 
 
The Static Configuration interface functions only with the EnRoute500’s wired 
interface.  Do  not  try  to  access the  EnRoute500  over  a  wireless  link  using  the 
address of this interface. 
 
To  connect  to  an  EnRoute500  using  its  Static  Configuration  IP  address,  you  must  configure 
your  computer’s  IP  address  to  be  in  the  169.254.253.253/16  subnet,  e.g.  169.254.253.1  and 
connect the computer’s Ethernet cable to the “DATA” port on the EnRoute500’s PoE injector. 
 
ENSURE THAT THE DATA CONNECTION FROM THE PC OR THE LAN IS MADE 
TO  THE  “PC”  PORT.  DO  NOT  CONNECT  ANY  DEVICE  OTHER  THAN  THE 
ENROUTE500  TO  THE  PORT  LABELED  “CPE”  ON  THE  PoE  INJECTOR. 
NETWORK  EQUIPMENT  THAT  DOES  NOT  SUPPORT  PoE  CAN  BE 
PERMANENTLY DAMAGED BY CONNECTING TO A PoE SOURCE. NOTE THAT 
MOST  ETHERNET  INTERFACES  ON  PERSONAL  COMPUTERS  (PCs), 
LAPTOP/NOTEBOOK  COMPUTERS,  AND  OTHER  NETWORK  EQUIPMENT 
(E.G. ETHERNET SWITCHES AND ROUTERS) DO NOT SUPPORT PoE.
 
 
Since the Static Configuration IP address is the same for all EnRoute500s, you 
should  not  simultaneously  connect  multiple  EnRoute500s  to  a  common  LAN 
and attempt to access them using the Static Configuration IP address.