Cross Point b.v. CP321AMD Manuale Utente

Pagina di 26
NEXUS AM Deactivator 
 
 
 
 
 
AM operating principle 
v2.1 
Page 12 of 26 
AM operating principle 
The  NEXUS  AM  Deactivator  operates  on  the  pulse-listening  principle.  Using  the  zero 
crossing  of  the  50Hz  mains  frequency  as  a  trigger,  a  short  burst  of  58kHz  signal  is 
transmitted and a receiver window is ‘opened’ after the transmission burst has stopped.  
If  a  label/tag  was  present  within  detection  range  during  the  transmission  burst,  the 
resonance  of  this  label/tag  will  be  detected  in  the  receiver  window  and  a  deactivation 
burst is triggered. 
A single 50Hz mains frequency cycle is dived into three phases; phase A, B and C. Each 
phase covers 1/3 of the 50Hz cycle duration. 
A  noise  reference  window  is  opened  to  detect  the  environmental  noise.  This  signal  is 
compared  with  the  signal  received  in  the  receiver  window  and  allows  the  software  to 
properly distinguish a tag signal from a noise signal. 
shows the AM operating principle (at 50Hz, with a default delay of 200μs) during 
one 50Hz cycle. 
 
Figure 5: AM operating principle 
 
Tr
a
n
s
mi
s
s
ion
 b
u
rs
R
e
c
e
iv
e
r w
ind
o
w
 
 
R
e
fe
re
n
c
e
 w
in
d
o
w
 
 
Phase C 
Phase B 
Phase A