NEXUS AM Deactivator 
 
 
 
 
 
AM operating principle 
v2.1 
Page 12 of 26 
AM operating principle 
The  NEXUS  AM  Deactivator  operates  on  the  pulse-listening  principle.  Using  the  zero 
crossing  of  the  50Hz  mains  frequency  as  a  trigger,  a  short  burst  of  58kHz  signal  is 
transmitted and a receiver window is ‘opened’ after the transmission burst has stopped.  
If  a  label/tag  was  present  within  detection  range  during  the  transmission  burst,  the 
resonance  of  this  label/tag  will  be  detected  in  the  receiver  window  and  a  deactivation 
burst is triggered. 
A single 50Hz mains frequency cycle is dived into three phases; phase A, B and C. Each 
phase covers 1/3 of the 50Hz cycle duration. 
A  noise  reference  window  is  opened  to  detect  the  environmental  noise.  This  signal  is 
compared  with  the  signal  received  in  the  receiver  window  and  allows  the  software  to 
properly distinguish a tag signal from a noise signal. 
shows the AM operating principle (at 50Hz, with a default delay of 200μs) during 
one 50Hz cycle. 
 
Figure 5: AM operating principle 
 
Tr
a
n
s
mi
s
s
ion
 b
u
rs
R
e
c
e
iv
e
r w
ind
o
w
 
 
R
e
fe
re
n
c
e
 w
in
d
o
w
 
 
Phase C 
Phase B 
Phase A