Linking Scanner to Base
When newly shipped or defaulted to factory settings, the base and scanner are 
not linked.  Once the scanner is placed into the base, the software automatically 
links  the scanner and the base.  If the scanner and base have previously been 
linked, you do not receive any feedback.  If this is the first time that the scanner 
and base are linked, both devices emit a short chirp when their radios link.
1. Provide power to the base.
2. Place the IT5620 into the base.  The scanner and base link.
3. To determine if your cordless system is set up correctly, scan one of the 
sample bar codes in the back of this manual.  If the scanner provides a 
single good read beep and the green LED lights, the scanner has 
successfully linked to the base.  If you receive a triple error beep and the red 
LED lights, the scanner has not linked to the base.
Unlinking the Scanner
If the base has a scanner linked to it, that scanner must be unlinked before a new 
scanner can be linked.  Once the previous scanner is unlinked, it will no longer 
communicate with the base.  To unlink a scanner from the base, scan the Unlink 
Scanner bar code below.
Link Modes
There are two link modes to accommodate different applications: Locked Link 
Mode and Open Link Mode.  Scan the appropriate bar codes included in the 
Open Link and Locked Link Mode explanations that follow to switch from one 
mode to another.  
Default = Locked Link Mode.
IT5620 Imager
IT2020 Cordless Base
Green LED
Red LED
Unlink Scanner